Back Button ADS5547 Datasheet HTML 37Page - Texas Instruments ADS5547 Datasheet HTML 38Page - Texas Instruments ADS5547 Datasheet HTML 39Page - Texas Instruments ADS5547 Datasheet HTML 40Page - Texas Instruments ADS5547 Datasheet HTML 41Page - Texas Instruments ADS5547 Datasheet HTML 42Page - Texas Instruments ADS5547 Datasheet HTML 43Page - Texas Instruments ADS5547 Datasheet HTML 44Page - Texas Instruments ADS5547 Datasheet HTML 45Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 41 / 57 page
background image
www.ti.com
CLKOUTP
D0_D1_P,
D0_D1_M
D2_D3_P,
D2_D3_M
D4_D5_P,
D4_D5_M
D6_D7_P,
D6_D7_M
D8_D9_P,
D8_D9_M
D10_D11_P,
D10_D11_M
D0
D2
D4
D6
D8
D10
SampleN+1
SampleN
D0
D2
D4
D6
D8
D10
D1
D3
D5
D7
D9
D11
D1
D3
D5
D7
D9
D11
CLKOUTM
LVDS Buffer Current Programmability
LVDS Buffer Internal Termination
ADS5527
SLWS196A – DECEMBER 2006 – REVISED MAY 2007
Figure 49. DDR LVDS Interface
The default LVDS buffer output current is 3.5 mA. When terminated by 100
Ω, this results in a 350-mV
single-ended voltage swing (700-mVPP differential swing). The LVDS buffer currents can also be programmed to
2.5 mA, 4.5 mA, and 1.75 mA using the register bits <LVDS CURR> (Table 17). In addition, there exists a
current double mode, where this current is doubled for the data and output clock buffers (register bits <CURR
DOUBLE>, Table 18).
An internal termination option is available (using the serial interface), by which the LVDS buffers are differentially
terminated inside the device. The termination resistences available are – 325, 200, and 170
Ω (nominal with
±20% variation). Any combination of these three terminations can be programmed; the effective termination is
the parallel combination of the selected resistences. This results in eight effective terminations from open (no
termination) to 75
Ω.
The internal termination helps to absorb any reflections coming from the receiver end, improving the signal
integrity. With 100-
Ω internal and 100-Ω external termination, the voltage swing at the receiver end is halved
(compared to no internal termination). The voltage swing can be restored by using the LVDS current double
mode. Figure 50 shows the eye diagram of one of the LVDS data outputs with a 10-pF load capacitance (from
each pin to ground) and 100-
Ω internal termination enabled. The termination can be programmed using register
bits <DATA TERM> and <CLKOUT TERM> (Table 17).
41
Submit Documentation Feedback



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com