66 / 95 page ![]() Datasheet, Public Page 65 [v2-00] 2023-Jan-12 Document Feedback TMD3719 − Register Overview Status Registers The primary status register for TMD3719 indicates if there are saturation or interrupt events that need to be handled by the user. This register is self-clearing, meaning that writing a 1 to any bit in the register clears that status bit. In this way, the user should read the STATUS register, handle all indicated event(s), then write the register value back to STATUS to clear the handled events. Writing 0 to these bits will not clear those bits if they have a value of 1, which means that new events that occurred since the last read of the STATUS register will not be accidentally cleared. Figure 73: STATUS Note(s): 1. Return to the Register Map (0xB7) Addr: 0xB7 STATUS Bit Field Reset Type Bit Description 7ASAT 0 R ALS Saturation. If ASIEN is set, indicates ALS saturation. Check the STATUS3 register to differentiate between analog or digital saturation. 6FDSAT 0 R Flicker Detection Saturation. If FDSIEN is set, indicates Flicker Detection saturation. Check the STATUS4 register to differentiate between analog or digital saturation. 5PSAT 0 R Proximity Saturation. If PSIEN is set, indicates analog saturation during a previous proximity cycle. Check the STATUS2 register to differentiate between ambient or reflected light saturation. 4PINT 0 R Proximity Interrupt One. If PIEN is set, indicates that a proximity detect or release event that met the programmed proximity thresholds and persistence occurred. 3AINT 0 R ALS Interrupt. If AIEN is set, indicates that an ALS event that met the programmed ALS thresholds and persistence occurred. 2FINT 0 R FIFO Buffer Interrupt. If FIEN is set, indicates that the FIFO_LVL fulfills the threshold condition. If cleared by writing 1, the interrupt will be asserted again as more data is collected. To fully clear this interrupt, all data must be read from the FIFO buffer. 1CINT 0 R Calibration Interrupt. If CIEN is set, indicates that either calibration is finished or that one of certain events have occurred during normal operation. If each function is enabled, CINT will be asserted if too many zeros occur too often in a period of samples, if the proximity baseline has decreased, or if at least one offset register has been adjusted. Check the CALIBSTAT register to identify the triggering event(s). 0SINT 0 R System Interrupt. If SIEN is set, indicates that one or more of several events has occurred or is complete. The events related to this interrupt are indicated in the STATUS5 register (0xBB): flicker detection register status has changed. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |