Back Button TMD3719 Datasheet HTML 45Page - OSRAM GmbH TMD3719 Datasheet HTML 46Page - OSRAM GmbH TMD3719 Datasheet HTML 47Page - OSRAM GmbH TMD3719 Datasheet HTML 48Page - OSRAM GmbH TMD3719 Datasheet HTML 49Page - OSRAM GmbH TMD3719 Datasheet HTML 50Page - OSRAM GmbH TMD3719 Datasheet HTML 51Page - OSRAM GmbH TMD3719 Datasheet HTML 52Page - OSRAM GmbH TMD3719 Datasheet HTML 53Page - OSRAM GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 49 / 95 page
background image
Page 48
Datasheet, Public
Document Feedback
[v2-00] 2023-Jan-12
TMD3719 − Register O ver view
Figure 50:
AGC_ENABLE
Note(s):
1. Return to the Register Map (0x8D)
Addr: 0x8D
AGC_ENABLE
Bit
Field
Reset
Type
Bit Description
7AGC_ENABLE_MOD_7
0
R/W
AGC Enable Modulator Seven. If asserted, then
device will use automatic gain control for the
modulator seven to maximize ALS signal while
avoiding saturation.
6AGC_ENABLE_MOD_6
0
R/W
AGC Enable Modulator Six. If asserted, then
device will use automatic gain control for the
modulator six to maximize ALS signal while
avoiding saturation.
5AGC_ENABLE_MOD_5
0
R/W
AGC Enable Modulator Five. If asserted, then
device will use automatic gain control for the
modulator five to maximize ALS signal while
avoiding saturation.
4AGC_ENABLE_MOD_4
0
R/W
AGC Enable Modulator Four. If asserted, then
device will use automatic gain control for the
modulator four to maximize ALS signal while
avoiding saturation.
3AGC_ENABLE_MOD_3
0
R/W
AGC Enable Modulator Three. If asserted, then
device will use automatic gain control for the
modulator three to maximize ALS signal while
avoiding saturation.
2AGC_ENABLE_MOD_2
0
R/W
AGC Enable Modulator Two. If asserted, then
device will use automatic gain control for the
modulator two to maximize ALS signal while
avoiding saturation.
1AGC_ENABLE_MOD_1
0
R/W
AGC Enable Modulator One. If asserted, then
device will use automatic gain control for the
modulator one to maximize ALS signal while
avoiding saturation.
0AGC_ENABLE_MOD_0
0
R/W
AGC Enable Modulator Zero. If asserted, then
device will use automatic gain control for the
modulator zero to maximize ALS signal while
avoiding saturation.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com