| Electronic Components Datasheet Search |
|
ADE9178 Datasheet(PDF) 51 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE9178 Datasheet(HTML) 51 Page - Analog Devices |
|
51 / 122 page ![]() Data Sheet ADE9178 THEORY OF OPERATION analog.com Rev. A | 51 of 122 Table 27. ERROR_STATUS Register Table ERROR_STATUS Bit Description Possible Cause of Issue How to Debug during Development How to Handle in the Field ADC_INIT_ERROR[0] Error occurred in ADC initialization. 1. ADC SPI signal integrity issue. 2. Error in ADCs. 1. Check signal integrity of SPI connections between the ADE9178 and ADCs. 2. See the Quick Start section and ensure that ADC related parameters are configured properly. 3. Read STATUS registers of ADCs to check if any error bits are set. 4. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. 1. Read STATUS registers of ADCs to check if any error bits are set. 2. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. ERROR0[1] Internal Error Occurred. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. ERROR1[2] Internal Error Occurred. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. ERROR2[3] Internal Error Occurred. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. ERROR3[4] Internal Error Occurred. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. ERROR4[5] Internal Error Occurred. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. ADC_CRC_ERROR[6] ADC SPI CRC Error Occurs. ADC SPI CRC errors are detected on the samples read from the ADCs. 1. Check signal integrity of SPI connections between the ADE9178 and ADCs. 2. Ensure that the ADC related registers are configured correctly as per the Quick Start section. 3. Read STATUS registers of ADCs to check if any error bits are set. 4. If error persists, reset the ADE9178 and ADCs and perform ADC initialization again. If CRC error occurs, the ADE9178 automatically discards the ADC samples, and previous good samples are used for measurements. ERROR5[7] Internal Error Occurred. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. Reset the ADE9178 and ADCs. Initialize ADCs using ADC_INIT of ADC_CONTROL register after ADE9178 reset. DREADY_FREQ_ERROR[8] ADC Data Ready Frequency Error. This bit is set when ADC Data Ready frequency is not 4 ADC DREADY frequency might be configured wrong. ADCs reset while ADC is running. 1. Check signal integrity of the DREADY signal. 2. Reset the ADE9178 and ADCs. Initialize ADCs using Clear DREADY_FREQ_ERR bit by writing 1 to bit 8 of ER- ROR_STATUS register. If the bit re-asserts reset the ADE9178 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |