21 / 29 page ![]() Preliminary Technical Data AD5420 Rev. PrD | Page 21 of 29 DEFAULT CONFIGURATION On initial power-up of the AD5420, the power-on-reset circuit ensures that all registers are loaded with zero-code, as such the default output range is 4mA to 20mA. The current output until a value is programmed is 0mA. An alternative current range may be selected via the CONTROL register. TRANSFER FUNCTION For the 0 to 20mA, 0 to 24mA and 4 to 20mA current output ranges the output current expressions are respectively given by; D mA I N OUT × ⎥⎦ ⎤ ⎢⎣ ⎡ = 2 20 D mA I N OUT × ⎥⎦ ⎤ ⎢⎣ ⎡ = 2 24 mA D mA I N OUT 4 2 16 + × ⎥⎦ ⎤ ⎢⎣ ⎡ = where: D is the decimal equivalent of the code loaded to the DAC. N is the bit resolution of the DAC. DATA REGISTER The DATA register is addressed by setting the control word of the input shift register to 0x01. The data to be written to the DATA register is entered in positions D15 to D0 as shown in Table 11, Table 11. Programming the Data Register MSB LSB D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 DATA WORD CONTROL REGISTER The CONTROL register is addressed by setting the control word of the input shift register to 0x55. The data to be written to the CONTROL register is entered in positions D15 to D0 as shown in Table 12. The CONTROL register functions are shown in Table 13. Table 12. Programming the CONTROL Register MSB LSB D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 0 0 REXT OUTEN SR CLOCK SR STEP SREN DCEN R2 R1 R0 Table 13. Control Register Functions Option Description REXT Setting this bit selects the external current setting resistor, Further details in Features section OUTEN Output enable. This bit must be set to enable the output. SR CLOCK See Features Section. Digital Slew Rate Control SR STEP See Features Section. Digital Slew Rate Control SREN Digital Slew Rate Control enable DCEN Daisychain enable R2,R1,R0 Output range select. See Table 14 Table 14. Output Range Options R2 R1 R0 Output Range Selected 1 0 1 4 to 20 mA Current Range 1 1 0 0 to 20 mA Current Range 1 1 1 0 to 24 mA Current Range |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |