Back Button AD7190 Datasheet HTML 12Page - Analog Devices AD7190 Datasheet HTML 13Page - Analog Devices AD7190 Datasheet HTML 14Page - Analog Devices AD7190 Datasheet HTML 15Page - Analog Devices AD7190 Datasheet HTML 16Page - Analog Devices AD7190 Datasheet HTML 17Page - Analog Devices AD7190 Datasheet HTML 18Page - Analog Devices AD7190 Datasheet HTML 19Page - Analog Devices AD7190 Datasheet HTML 20Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 21 page
background image
AD7190
Preliminary Technical Data
Rev.PrD 7/08 | Page 16
STATUS REGISTER
(RS2, RS1, RS0 = 0, 0, 0; Power-On/Reset = 0x80)
The status register is an 8-bit read-only register. To access the ADC status register, the user must write to the communications register,
select the next operation to be a read, and load Bit RS2, Bit RS1, and Bit RS0 with 0. Table 15 outlines the bit designations for the status
register. SR0 through SR7 indicate the bit locations, SR denoting the bits are in the status register. SR7 denotes the first bit of the data
stream. The number in brackets indicates the power-on/reset default status of that bit.
SR7
SR6
SR5
SR4
SR3
SR2
SR1
SR0
RDY(1)
ERR(0)
NOREF(0)
PARITY(0)
CHD3(0)
CHD2(0)
CHD1(0)
CHD0(0)
Table 15. Status Register Bit Designations
Bit Location
Bit Name
Description
SR7
RDY
Ready Bit for ADC. Cleared when data is written to the ADC data register. The RDY bit is set automatically
after the ADC data register has been read or a period of time before the data register is updated with a
new conversion result to indicate to the user not to read the conversion data. It is also set when the part is
placed in power-down mode, idle mode or when SYNC is taken low.
The end of a conversion is also indicated by the DOUT/RDY pin. This pin can be used as an alternative to
the status register for monitoring the ADC for conversion data.
SR6
ERR
ADC Error Bit. This bit is written to at the same time as the RDY bit. Set to indicate that the result written to
the ADC data register has been clamped to all 0s or all 1s. Error sources include overrange, underrange, or
the absence of a reference voltage. Cleared by a write operation to start a conversion.
SR5
NOREF
No External Reference Bit. Set to indicate that the selected reference (REFIN1 or REFIN2) is at a voltage that
is below a specified threshold. When set, conversion results are clamped to all ones. Cleared to indicate
that a valid reference is applied to the selected reference pins. The NOXREF bit is enabled by setting the
REF_DET bit in the configuration register to 1. The ERR bit is also set if the voltage applied to the selected
reference input is invalid.
SR4
PARITY
Parity Check of Data Register.
If the ENPAR bit is set, the PARITY bit is set if there is an odd number of 1s in the data register. It is cleared if
there is an even number of 1s in the data register. The DAT_STA bit should be set when the parity check is
used. When the DAT_STA bit is set, the contents of the status register are transmitted along with the data
for each data register read.
SR3 to SR0
CHD3 to
CHD0
These bits indicate which channel corresponds to the data register contents. They do not indicate which
channel is presently being converted but indicate which channel was selected when the conversion
contained in the data register was being generated.
MODE REGISTER
(RS2, RS1, RS0 = 0, 0, 1; Power-On/Reset = 0x080060)
The mode register is a 24-bit register from which data can be read or to which data can be written. This register is used to select the
operating mode, the update rate, and the clock source. Table 16 outlines the bit designations for the mode register. MR0 through MR23
indicate the bit locations, MR denoting the bits are in the mode register. MR23 denotes the first bit of the data stream. The number in
brackets indicates the power-on/reset default status of that bit. Any write to the mode register resets the modulator and filter and sets the
RDY bit.
MR23
MR22
MR21
MR20
MR19
MR18
MR17
MR16
MD2(0)
MD1(0)
MD0(0)
DAT_STA(0)
CLK1(1)
CLK0(0)
0
0
MR15
MR14
MR13
MR12
MR11
MR10
MR9
MR8
SINC3(0)
0
ENPAR(0)
0
SINGLE(0)
REJ60(0)
FS9(0)
FS8(0)
MR7
MR6
MR5
MR4
MR3
MR2
MR1
MR0
FS7(0)
FS6(1)
FS5(1)
FS4(0)
FS3(0)
FS2(0)
FS1(0)
FS0(0)
Table 16. Mode Register Bit Designations
Bit Location
Bit Name
Description
MR23 to MR21
MD2 to MD0
Mode Select Bits. These bits select the operational mode of the AD7190 (see Table 17).
MR20
DAT_STA
Transmit status register contents after each data register read.
When DAT_STA is set, the contents of the status register are transmitted along with each data register



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com