16 / 21 page ![]() AD7190 Preliminary Technical Data Rev.PrD 7/08 | Page 16 STATUS REGISTER (RS2, RS1, RS0 = 0, 0, 0; Power-On/Reset = 0x80) The status register is an 8-bit read-only register. To access the ADC status register, the user must write to the communications register, select the next operation to be a read, and load Bit RS2, Bit RS1, and Bit RS0 with 0. Table 15 outlines the bit designations for the status register. SR0 through SR7 indicate the bit locations, SR denoting the bits are in the status register. SR7 denotes the first bit of the data stream. The number in brackets indicates the power-on/reset default status of that bit. SR7 SR6 SR5 SR4 SR3 SR2 SR1 SR0 RDY(1) ERR(0) NOREF(0) PARITY(0) CHD3(0) CHD2(0) CHD1(0) CHD0(0) Table 15. Status Register Bit Designations Bit Location Bit Name Description SR7 RDY Ready Bit for ADC. Cleared when data is written to the ADC data register. The RDY bit is set automatically after the ADC data register has been read or a period of time before the data register is updated with a new conversion result to indicate to the user not to read the conversion data. It is also set when the part is placed in power-down mode, idle mode or when SYNC is taken low. The end of a conversion is also indicated by the DOUT/RDY pin. This pin can be used as an alternative to the status register for monitoring the ADC for conversion data. SR6 ERR ADC Error Bit. This bit is written to at the same time as the RDY bit. Set to indicate that the result written to the ADC data register has been clamped to all 0s or all 1s. Error sources include overrange, underrange, or the absence of a reference voltage. Cleared by a write operation to start a conversion. SR5 NOREF No External Reference Bit. Set to indicate that the selected reference (REFIN1 or REFIN2) is at a voltage that is below a specified threshold. When set, conversion results are clamped to all ones. Cleared to indicate that a valid reference is applied to the selected reference pins. The NOXREF bit is enabled by setting the REF_DET bit in the configuration register to 1. The ERR bit is also set if the voltage applied to the selected reference input is invalid. SR4 PARITY Parity Check of Data Register. If the ENPAR bit is set, the PARITY bit is set if there is an odd number of 1s in the data register. It is cleared if there is an even number of 1s in the data register. The DAT_STA bit should be set when the parity check is used. When the DAT_STA bit is set, the contents of the status register are transmitted along with the data for each data register read. SR3 to SR0 CHD3 to CHD0 These bits indicate which channel corresponds to the data register contents. They do not indicate which channel is presently being converted but indicate which channel was selected when the conversion contained in the data register was being generated. MODE REGISTER (RS2, RS1, RS0 = 0, 0, 1; Power-On/Reset = 0x080060) The mode register is a 24-bit register from which data can be read or to which data can be written. This register is used to select the operating mode, the update rate, and the clock source. Table 16 outlines the bit designations for the mode register. MR0 through MR23 indicate the bit locations, MR denoting the bits are in the mode register. MR23 denotes the first bit of the data stream. The number in brackets indicates the power-on/reset default status of that bit. Any write to the mode register resets the modulator and filter and sets the RDY bit. MR23 MR22 MR21 MR20 MR19 MR18 MR17 MR16 MD2(0) MD1(0) MD0(0) DAT_STA(0) CLK1(1) CLK0(0) 0 0 MR15 MR14 MR13 MR12 MR11 MR10 MR9 MR8 SINC3(0) 0 ENPAR(0) 0 SINGLE(0) REJ60(0) FS9(0) FS8(0) MR7 MR6 MR5 MR4 MR3 MR2 MR1 MR0 FS7(0) FS6(1) FS5(1) FS4(0) FS3(0) FS2(0) FS1(0) FS0(0) Table 16. Mode Register Bit Designations Bit Location Bit Name Description MR23 to MR21 MD2 to MD0 Mode Select Bits. These bits select the operational mode of the AD7190 (see Table 17). MR20 DAT_STA Transmit status register contents after each data register read. When DAT_STA is set, the contents of the status register are transmitted along with each data register |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |