| Electronic Components Datasheet Search |
|
SC908 Datasheet(PDF) 8 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC908 Datasheet(HTML) 8 Page - Semtech Corporation |
|
8 / 30 page ![]() SC908 8 Notes: (1) VAD OP is the “Maximum Vsupply” as defined in EIA/JEDEC Standard No. 78, paragraph 2.11. (2) The value of the buck converter disabled battery leakage current is included in the charger section battery leakage since it cannot be independently measured (because SVIN is tied to BAT internally). The buck converter contribution to this value is also included in the Buck Converter section for design guidance only. (3) VSYS regulation voltage assumes that V VAD exceeds V VSYS by the VSYS regulator dropout (typically 0.5V at 5mA, for a minimum regulator R DS = 71Ω). If this condition is not met, then V VSYS = V VAD minus the VSYS regulator dropout. (4) I Q-Core is the supply current from the battery for common reference circuits into the BAT pin when either the buck converter or LDO or charger are enabled. (5) t SU_REF is the start-up time of the voltage reference buffer for both the DC-DC buck converter and the LDO, and should be added to the start-up time (t SU-SVOUT or t SU-LVOUT respectively) of the first regulator enabled. In the case of the LDO start-up with the switcher disabled, the LDO start-up time t SU-LVOUT is concurrent with the reference start-up time t SU_REF , and so t SU-LVOUT is specified as typically zero. (6) SVOUT is the buck converter output node, which is the node at which the output inductor is connected to the load. It is the top of the feedback resistor divider network. See the Typical Application Circuit. (7) To guarantee positive load threshold hysteresis for PSAVE-to-PWM mode switching with SVOUT > 2.2V, contact your Semtech representative for application assistance. (8) If V BAT < V SVOUT_Max / SDC MAX + 150mV, then the maximum output setting is V BAT x SDC MAX + 150mV. Higher output voltage settings are feasible, but are subject to load-dependent dropout. (9) Specified with V BAT = V LVIN . (10) Guaranteed by design. Parameter Symbol Conditions Min Typ Max Units Logic Control Inputs & Status Outputs Battery Detector Sense Leakage (BSEN Current) I BSEN_DET V VAD > VAD UVLO , or SEN or LEN high, V BSEN = 4.2V 510 μA Battery Detector Activation Delay(10) V DET_DEL Time from first of LEN or SEN high until LBATB/FAULTB valid, V VAD = 0V 70 μs Logic Input Low V IL LEN, SEN; V BAT = 2.7V 0.4 V Logic Input High V IH LEN, SEN; V BAT = 2.7V 1.5 V Logic Input Current High I IL LEN, SEN; V BAT = 2.7V 1 μA Logic Input Current Low I IH LEN, SEN; V BAT = 2.7V 1.5 μA CPB, CHRGB, FLTB, LBATB Outputs V OL I SINK = 2mA 0.5 V I OH V = 5V (V VAD = 8V for CPB) 1 μA Electrical Characteristics (continued) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |