LMP8358 Datasheet(PDF) 24 Page - National Semiconductor (TI)

[Old version datasheet] Texas Instruments acquired National semiconductor. Click here to check the latest version.
Part # LMP8358
Description  Zero-Drift, Programmable Instrumentation Amplifier with Diagnostics
PDF  32 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  NSC [National Semiconductor (TI)]
Direct Link  http://www.national.com
Logo NSC - National Semiconductor (TI)

LMP8358 Datasheet(HTML) 24 Page - National Semiconductor (TI)

Back Button LMP8358 Datasheet HTML 20Page - National Semiconductor (TI) LMP8358 Datasheet HTML 21Page - National Semiconductor (TI) LMP8358 Datasheet HTML 22Page - National Semiconductor (TI) LMP8358 Datasheet HTML 23Page - National Semiconductor (TI) LMP8358 Datasheet HTML 24Page - National Semiconductor (TI) LMP8358 Datasheet HTML 25Page - National Semiconductor (TI) LMP8358 Datasheet HTML 26Page - National Semiconductor (TI) LMP8358 Datasheet HTML 27Page - National Semiconductor (TI) LMP8358 Datasheet HTML 28Page - National Semiconductor (TI) Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 32 page
background image
floating. When MUX[1:0] = 01b and POL = 1b both inputs are
connected to the -IN pin of the LMP8358. The +IN pin is left
floating.
Compare Input to V-
When MUX[1:0] = 10b or 11b one external input of the
LMP8358 is floating. The other external input is divided by 50
as shown in Table 9. Input Multiplexer and Polarity (Register
bits 8:6). The internal instrumentation amplifier input that is
not connected to the external pin is connected to V−. With a
scale factor of 1/50 this gives an overall gain of 0.2x, 0.4x, 1x,
2x, 4x, 10x, or 20x depending on what the gain is set to with
G[2:0] bits as shown in Table 10. Overall Gain using G[2:0],
MUX[1:0] and POL.
Table 10. Overall Gain using G[2:0], MUX[1:0] and POL
G[2:0]
MUX[1:0]
Overall System Gain
POL = 0b
POL = 1b
000b
10b or 11b
0.2
−0.2
001b
10b or 11b
0.4
−0.4
010b
10b or 11b
1
−1
011b
10b or 11b
2
−2
100b
10b or 11b
4
−4
101b
10b or 11b
10
−10
110b
10b or 11b
20
−20
Shutdown Enable (Serial, Parallel)
When the SHDN bit of the LMP8358 register is set to 1b the
part is put into shutdown mode. It will use less than 1
μA in this
state.
Table 11. Shutdown (Register bit 9)
SHDN
Mode
0
Active mode
1
Shutdown mode
Filter and External Filter Capacitor (Serial)
The FILT bit controls the state of switch S2 shown in the Block
Diagram. When G[2:0] = 000b to 110b, switch S2 will be open
if FILT = 0b and S2 will be closed if FILT = 1b. When G[2:0]
= 111b switch S2 is always closed and does not depend on
the value in the FILT bit.
When FILT = 1b and COMP[2:0] = 1xxb the LMP8358 is unity-
gain stable and an external filter cap can be applied as shown
in Figure 6. The corner filter of the filter is:
F
-3dB = 1/(2πRFILTERCFILTER)
R
FILTER depends on the gain of the part and is shown inTable
13. RFILTER Value.
Table 12. Filter (Register bit 10)
FILT
Mode
0
No external filter cap used
1
External filter cap used
Table 13. R
FILTER Value
Gain
R
FILTER Value
10
18.5 k
Ω
20
112 k
Ω
50
168 k
Ω
100
187 k
Ω
200
1.12 M
Ω
500
1.68 M
Ω
1000
1.87 M
Ω
User-Defined Gain
External Resistor R1
The tolerance of the R
FILTER value for the pre-defined gains
is about ±3%. If an external filter cap is not used FILT should
be set to 0b to prevent errors related to leakage currents on
the FB pin.
Fault Detection Pin and Current Setting (Serial)
The LMP8358 has an internal current source that can be used
to detect faults in the overall system. See the FAULT DE-
TECTION METHODS Section. When PIN = 0b this current
source is connected to the +IN pin. When PIN = 1b the current
source is connected to the −IN pin.
Table 14. Pin Current Source (Register bit 11)
PIN
Current source is connected to
0
+IN pin
1
−IN pin
The Fault Detection Current bit, CUR[2:0] controls the amount
of current that sent to the input pin as shown in Table 15. Fault
Detection Current Source (Register bits 14:12).
Table 15. Fault Detection Current Source (Register bits
14:12)
CUR2 CUR1 CUR0
0
0
0
disconnected and powered down *
0
0
1
10 nA
0
1
0
100 nA
0
1
1
1 μA
1
0
0
10 µA
1
0
1
100 µA
1
1
0
disconnected, but powered *
1
1
1
Do Not Use
* Leaving the fault detection current source powered allows it
to switch between current levels faster, particularly when sup-
plying currents less than 1 µA.
www.national.com
24



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com