LMP8358 Datasheet(PDF) 27 Page - National Semiconductor (TI)

[Old version datasheet] Texas Instruments acquired National semiconductor. Click here to check the latest version.
Part # LMP8358
Description  Zero-Drift, Programmable Instrumentation Amplifier with Diagnostics
PDF  32 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  NSC [National Semiconductor (TI)]
Direct Link  http://www.national.com
Logo NSC - National Semiconductor (TI)

LMP8358 Datasheet(HTML) 27 Page - National Semiconductor (TI)

Back Button LMP8358 Datasheet HTML 23Page - National Semiconductor (TI) LMP8358 Datasheet HTML 24Page - National Semiconductor (TI) LMP8358 Datasheet HTML 25Page - National Semiconductor (TI) LMP8358 Datasheet HTML 26Page - National Semiconductor (TI) LMP8358 Datasheet HTML 27Page - National Semiconductor (TI) LMP8358 Datasheet HTML 28Page - National Semiconductor (TI) LMP8358 Datasheet HTML 29Page - National Semiconductor (TI) LMP8358 Datasheet HTML 30Page - National Semiconductor (TI) LMP8358 Datasheet HTML 31Page - National Semiconductor (TI) Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 32 page
background image
Shorted Inputs
Figure 11 shows the inputs of the LMP8358 shorted. To detect
this fault set CUR[2:0] = 101b to inject a 100µA current and
set the gain to 10× (5000x). The LMP8358 is set up with nor-
mal differential inputs. The output will read about 0.07V be-
cause of the voltage drop across the internal ESD resistor,
which has a value between 60
Ω to 90Ω. If the gain is set to
100× with an injected current of 100µA the output will be about
0.7V.
300454b9
FIGURE 11. Shorted Inputs
Degraded Input Line
Figure 12 shows an example of a degraded connection be-
tween the bridge and the +IN pin of the LMP8358. This fault
is shown by the 1 k
Ω resistor placed between the bridge and
the LMP8358. To detect this fault use the 1/50 feature by set-
ting MUX[1:0] to 10b to test the +IN pin, POL to 0b, and G[2:0]
to 010b for a gain of 50. This will give an overall gain of 1. Set
CUR[2:0] = 101b to inject a 100µA current and read the output
voltage (5082x). Next set MUX[1:0] to 11b and PIN to 1b to
test the −IN pin as shown in Figure 13 and read the output
(58C2x). If the voltages of these two measurements are dif-
ferent a degraded input fault exists.
300454c0
FIGURE 12. Degraded Input Line, Step 1
300454c1
FIGURE 13. Degraded Input Line, Step 2
27
www.national.com



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com