37 / 61 page ![]() PRELIMINARY 33 80960JD 4.5.1 AC Test Conditions and Derating Curves The AC Specifications in Section 4.5, AC Specifications are tested with the 50 pF load indicated in Figure 8. Figure 9 shows how timings vary with load capacitance; Figure 10 shows how output rise and fall times vary with load capacitance. Figure 8. AC Test Load Figure 9. Output Delay or Hold vs. Load Capacitance Output Pin CL = 50 pF for all signals CL 50 100 150 C L (pF) nom +4 nom +2 nom nom -2 AC Derating Curves nom +6 High-to-Low Transitions Low-to-High Transitions |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|