Back Button ADG5243F Datasheet HTML 22Page - Analog Devices ADG5243F Datasheet HTML 23Page - Analog Devices ADG5243F Datasheet HTML 24Page - Analog Devices ADG5243F Datasheet HTML 25Page - Analog Devices ADG5243F Datasheet HTML 26Page - Analog Devices ADG5243F Datasheet HTML 27Page - Analog Devices ADG5243F Datasheet HTML 28Page - Analog Devices ADG5243F Datasheet HTML 29Page - Analog Devices ADG5243F Datasheet HTML 30Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 27 / 30 page
background image
Data Sheet
ADG5243F
Rev. 0 | Page 27 of 30
USER DEFINED FAULT PROTECTION
POSFV and NEGFV are required secondary power supplies that
set the level at which the overvoltage protection is engaged. POSFV
can be supplied from 4.5 V to VDD, and NEGFV can be supplied
from VSS to 0 V. If a secondary supply is not available, connect
these pins to VDD (POSFV) and VSS (NEGFV). The overvoltage
protection then engages at the primary supply voltages. When
the voltages at the source inputs exceed POSFV or NEGFV by
VT, the switch turns off or, if the device is unpowered, the switch
remains off. The switch input remains high impedance regardless
of the digital input state and if it is selected, the drain pulls to
either POSFV or NEGFV. Signal levels up to +55 V and −55 V
are blocked in both the powered and unpowered condition as
long as the 80 V limitation between the source and supply pins
is met.
Power-On Protection
The following conditions must be satisfied for the switch to be
in the on condition:
•
The primary supply must be VDD to VSS ≥ 8 V.
•
For POSFV, the secondary supply must be between 4.5 V
and VDD, and for NEGFV, the secondary supply must be
between VSS and 0 V.
•
The input signal must be between NEGFV − VT and
POSFV + VT.
•
The digital logic control input has selected the switch.
When the switch is turned on, signal levels up to the secondary
supply rails are passed.
The switch responds to an analog input that exceeds POSFV or
NEGFV by a threshold voltage, VT, by turning off. The absolute
input voltage limits are −55 V and +55 V, while maintaining an
80 V limit between the source pin and the supply rails. The switch
remains off until the voltage at the source pin returns to
between POSFV and NEGFV.
The fault response time (tRESPONSE) when powered by ±15 V dual
supply is typically 90 ns and the fault recovery time (tRECOVERY) is
745 ns. These vary with supply voltages and output load conditions.
The maximum stress across the switch channel is 80 V, therefore,
the user must pay close attention to this limit under a fault
condition.
For example, consider the case where the device is set up in a
multiplexer configuration as shown in Figure 50.
•
VDD/VSS and POSFV/NEGFV = ±22 V, S1A = S2B= +22 V,
S1B = +55 V, and S2A = −55 V.
•
S1A and S2A are selected.
•
The voltage between S1B and D1 = +55 V − (22 V) = +33 V.
•
The voltage between S2B and D2 = +22 V − (−55 V) = +77 V.
These calculations are all within device specifications: a 55 V
maximum fault on the source inputs and a maximum of 80 V
across the off switch channel.
IN1 IN2 IN3 EN
ADG5243F
FAULT
DETECTION
AND SWITCH
DRIVER
VDD
VSS
GND
+22V
–22V
0V
+5V
0V
S1A
+22V
D1
S1B
+55V
S2B
+22V
D2
S2A
+55V
S3B
D3
S3A
Figure 50. ADG5243F in an Overvoltage Condition
Power-Off Protection
When no power supplies are present, the switch remains in the
off condition, and the switch inputs are high impedance. This
state ensures that no current flows and prevents damage to the
switch or downstream circuitry. The switch output is a virtual
open circuit.
The switch remains off regardless of whether the VDD and VSS
supplies are 0 V or floating. A GND reference must always be
present to ensure proper operation. Signal levels of up to ±55 V
are blocked in the unpowered condition.
Digital Input Protection
The ADG5243F can tolerate digital input signals being present
on the device without power. When the device is unpowered,
the switch is guaranteed to be in the off state, regardless of the
state of the digital logic signals.
The digital inputs are protected against positive faults of up to
44 V. The digital inputs do not offer protection against negative
overvoltages. ESD protection diodes connected to GND are
present on the digital inputs.
Overvoltage Interrupt Flag
The voltages on the source inputs of the ADG5243F are
continuously monitored, and the state of the switches is
indicated by an active low digital output pin, FF.
The voltage on the FF pin indicates if any of the source input pins
are experiencing a fault condition. The output of the FF pin is a
nominal 3 V when all source pins are within normal operating
range. If any source pin voltage exceeds the secondary supply
voltage by VT, the FF output reduces to below 0.4 V.
Use the specific fault digital output pin, SF, to decode which
inputs are experiencing a fault condition. The SF pin reduces to
below 0.4 V when a fault condition is detected on a specific pin,
depending on the state of F0, F1, and F2 (see Table 9).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com