24 / 77 page ![]() AD9690 Data Sheet ADC R1 R2 R1 0.1µF 0.1µF 0.1µF C2 R3 R3 BALUN NOTES 1. SEE TABLE 9 FOR COMPONENT VALUES. R2 C1 C1 Figure 64. Differential Transformer-Coupled Configuration for the AD9690 Table 9. Differential Transformer-Coupled Input Configuration Component Values Device Frequency Range Transformer R1 (Ω) R2 (Ω) R3 (Ω) C1 (pF) C2 (pF) AD9690-500 DC to 250 MHz ETC1-1-13 10 50 10 4 2 250 MHz to 2 GHz BAL-0006/BAL-0006SMG 10 50 10 4 2 AD9690-1000 DC to 500 MHz ECT1-1-13/BAL-0006SMG 25 25 10 4 2 500 MHz to 2 GHz BAL-0006/BAL-0006SMG 25 25 0 Open Open Input Common Mode The analog inputs of the AD9690 are internally biased to the common mode as shown in Figure 65. The common-mode buffer has a limited range in that the performance suffers greatly if the common-mode voltage drops by more than 100 mV. Therefore, in dc-coupled applications, set the common-mode voltage to 2.05 V, ±100 mV to ensure proper ADC operation. The full-scale voltage setting must be at a 1.7 V p-p differential if running in a dc-coupled application. Analog Input Buffer Controls and SFDR Optimization The AD9690 input buffer offers flexible controls for the analog inputs, such as input termination, buffer current, and input full- scale adjustment. All the available controls are shown in Figure 65. 10pF VIN+ VIN– AVDD3 AVDD3 AVDD3 VCM BUFFER 400Ω AVDD3 AVDD3 1.5pF 3pF 1.5pF 3pF AIN CONTROL SPI REGISTERS (0x008, 0x015, 0x016, 0x018, 0x019, 0x01A, 0x11A, 0x934, 0x935) Figure 65. Analog Input Controls Using the 0x018, 0x019, 0x01A, 0x11A, 0x934, and 0x935 registers, the buffer behavior on each channel can be adjusted to optimize the SFDR over various input frequencies and bandwidths of interest. Input Buffer Control Registers (0x018, 0x019, 0x01A, 0x935, 0x934, 0x11A) The input buffer has many registers that set the bias currents and other settings for operation at different frequencies. These bias currents and settings can be changed to suit the input frequency range of operation. Register 0x018 controls the buffer bias current to help with the kickback from the ADC core. This setting can be scaled from a low setting of 1.0× to a high setting of 8.5×. The default setting is 3.0× for the AD9690-1000, and 2.0× for the AD9690-500. These settings are sufficient for operation in the first Nyquist zone for the products. When the input buffer current in Register 0x018 is set, the amount of current required by the AVDD3 supply changes. This relationship is shown in Figure 66. For a complete list of buffer current settings, see Table 36. BUFFER CONTROL 1 SETTING 1.5× 2.5× 3.5× 4.5× 5.5× 6.5× 7.5× 8.5× AD9690-500 AD9690-1000 50 0 100 150 200 250 300 Figure 66. IAVDD3 vs. Buffer Control 1 Setting in Register 0x018 The 0x019, 0x01A, 0x11A, and 0x935 registers offer secondary bias controls for the input buffer for frequencies >500 MHz. Register 0x934 can be used to reduce input capacitance to achieve wider signal bandwidth but may result in slightly lower linearity and noise performance. These register settings do not impact the AVDD3 power as much as Register 0x018 does. For frequencies <500 MHz, it is recommended to use the default settings for these registers. Rev. 0 | Page 24 of 77 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |