21 / 25 page ![]() ADT75 Data Sheet Rev. B | Page 20 of 24 SMBus ALERT The OS/ALERT pin can behave as a SMBus alert pin when the SMBus alert function is enabled by setting Bit D7 in the configuration register. The interrupt mode must also be selected (Bit D1 in the configuration register). The OS/ALERT pin is an open-drain output and requires a pull-up to VDD. Several SMBus alert outputs can be wire-AND’ed together, so that the common line goes low if one or more of the SMBus alert outputs goes low. The polarity of the OS/ALERT pin must be set for active low for a number of outputs to be wire-AND’ed together. The OS/ALERT output can operate as a SMBALERT function. Slave devices on the SMBus normally cannot signal to the master that they want to talk, but the SMBALERT function allows them to do so. SMBALERT is used in conjunction with the SMBus general call address. One or more SMBus alert outputs can be connected to a common SMBALERT line connected to the master. When the SMBALERT line is pulled low by one of the devices, the following procedure occurs as shown in Figure 20. MASTER RECEIVES SMBALERT START ALERT RESPONSE ADDRESS RD ACK DEVICE ADDRESS MASTER SENDS ARA AND READ COMMAND DEVICE SENDS ITS ADDRESS NO ACK STOP Figure 20. ADT75 Responds to SMBALERT ARA 1. SMBALERT is pulled low. 2. Master initiates a read operation and sends the SMBus alert response address (ARA = 0001 100). This reserved SMBus/ I2C address must not be used as a specific device address. 3. The device whose SMBus alert output is low responds to the SMBus alert response address and the master reads its device address. As the device address is seven bits long, the ADT75’s LSB is free to be used as an indicator as to which temperature limit was exceeded. The LSB is high if the temperature is greater than or equal to TOS, and the LSB is low if the temperature is less than THYST. The address of the device is now known and it can be interrogated in the usual way. 4. If more than one devices’ SMBus alert output is low, the one with the lowest device address has priority, which is in accordance with normal SMBus specifications. Once the ADT75 has responded to the SMBus alert response address, it resets its SMBus alert output. If the SMBALERT line remains low, the master sends the ARA again. It continues to do this until all devices whose SMBALERT outputs were low have responded. START ALERT RESPONSE ADDRESS RD ACK DEVICE ADDRESS MASTER SENDS ARA AND READ COMMAND DEVICE SENDS ITS ADDRESS DEVICE ACK ACK PEC NO ACK STOP MASTER ACK MASTER NACK DEVICE SENDS ITS PEC DATA MASTER RECEIVES SMBALERT Figure 21. ADT75 Responds to SMBALERT ARA with Packet Error Checking (PEC) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |