| Electronic Components Datasheet Search |
|
AD7192 Datasheet(PDF) 29 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7192 Datasheet(HTML) 29 Page - Analog Devices |
|
29 / 41 page ![]() AD7192 Rev. A | Page 28 of 40 is 50 Hz (sinc4 filter); 50 Hz rejection is no longer achieved. The ADC must operate with an output data rate of 12.5 Hz to obtain 50 Hz rejection when zero latency is enabled. To obtain simultaneous 50 Hz/60 Hz rejection, the REJ60 bit in the mode register can be set when the output data rate is equal to 12.5 Hz. The stop-band attenuation is considerably reduced also (3 dB compared with 53 dB in the nonzero latency mode). 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 –100 0100 50 200 300 400 500 150 250 350 450 550 600 FREQUENCY (Hz) Figure 27. Sinc4 Filter Response (50 Hz Output Data Rate, Zero Latency) Channel Sequencer The AD7192 includes a channel sequencer, which simplifies communications with the device in multichannel applications. The sequencer also optimizes the channel throughput of the device because the sequencer switches channels at the optimum rate rather than waiting for instructions via the SPI interface. Bit CH0 to Bit CH7 in the configuration register are used to enable the required channels. In continuous conversion mode, the ADC selects each of the enabled channels in sequence and performs a conversion on the channel. The RDY pin goes low when a valid conversion is available on each channel. When several channels are enabled, the contents of the status register should be attached to the 24-bit word so that the user can identify the channel that corresponds to each conversion. To attach the status register value to the conversion, Bit DAT_STA in the mode register should be set to 1. When several channels are enabled, the ADC must allow the complete settling time to generate a valid conversion each time that the channel is changed. The AD7192 takes care of this: when a channel is selected, the modulator and filter are reset and the RDY pin is taken high. The AD7192 then allows the complete settling time to generate the first conversion. RDY goes low only when a valid conversion is available. The AD7192 then selects the next enabled channel and converts on that channel. The user can then read the data register while the ADC is performing the conversion on the next channel. The time required to read a valid conversion from all enabled channels is equal to tSETTLE × number of enabled channels For example, if the sinc4 filter is selected, chop is disabled, and zero latency is disabled, the settling time for each channel is equal to tSETTLE = 4/fADC where fADC is the output data rate when continuously converting on a single channel. The time required to sample N channels is 4/(fADC × N) RDY CONVERSIONS CHANNEL A CHANNEL B 1/fADC CHANNEL C Figure 28. Channel Sequencer DIGITAL INTERFACE As indicated in the On-Chip Registers section, the program- mable functions of the AD7192 are controlled using a set of on-chip registers. Data is written to these registers via the serial interface of the part. Read access to the on-chip registers is also provided by this interface. All communication with the part must start with a write to the communications register. After power-on or reset, the device expects a write to its communications register. The data written to this register determines whether the next oper- ation is a read operation or a write operation and also determines to which register this read or write operation occurs. Therefore, write access to any of the other registers on the part begins with a write operation to the communications register, followed by a write to the selected register. A read operation from any other register (except when continuous read mode is selected) starts with a write to the communications register, followed by a read operation from the selected register. The serial interface of the AD7192 consists of four signals: CS, DIN, SCLK, and DOUT/RDY. The DIN line is used to transfer data into the on-chip registers, and DOUT/RDY is used for accessing data from the on-chip registers. SCLK is the serial clock input for the device, and all data transfers (either on DIN or DOUT/RDY) occur with respect to the SCLK signal. The DOUT/RDY pin functions as a data ready signal also, the line going low when a new data-word is available in the output register. It is reset high when a read operation from the data register is complete. It also goes high prior to the updating of the data register to indicate when not to read from the device, to ensure that a data read is not attempted while the register is being updated. CS is used to select a device. It can be used to decode the AD7192 in systems where several components are connected to the serial bus. Figure 3 and Figure 4 show timing diagrams for interfacing to the AD7192, with CS being used to decode the part. shows the timing for a read operation from the output shift register of the AD7192, and shows the timing for a write operation to the input shift register. It is possible to read the same word from the data register several times even though the DOUT/ Figure 3 Figure 4 RDY |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |