MP8846 Datasheet(PDF) 18 Page - Monolithic Power Systems

Part # MP8846
Description  High-Efficiency, 6A, 8V, Synchronous Step-Down Converter with I2C Interface
PDF  27 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MPS [Monolithic Power Systems]
Direct Link  http://www.monolithicpower.com
Logo MPS - Monolithic Power Systems

MP8846 Datasheet(HTML) 18 Page - Monolithic Power Systems

Back Button MP8846 Datasheet HTML 14Page - Monolithic Power Systems MP8846 Datasheet HTML 15Page - Monolithic Power Systems MP8846 Datasheet HTML 16Page - Monolithic Power Systems MP8846 Datasheet HTML 17Page - Monolithic Power Systems MP8846 Datasheet HTML 18Page - Monolithic Power Systems MP8846 Datasheet HTML 19Page - Monolithic Power Systems MP8846 Datasheet HTML 20Page - Monolithic Power Systems MP8846 Datasheet HTML 21Page - Monolithic Power Systems MP8846 Datasheet HTML 22Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 27 page
background image
MP8846 – 6A, 8V SYNCHRONOUS STEP-DOWN CONVERTER
MP8846 Rev. 1.0
www.MonolithicPower.com
18
5/19/2015
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2015 MPS. All Rights Reserved.
I2C INTERFACE
I2C Serial Interface Description
The I2C is a 2-wire, bidirectional serial interface
consisting of a data line (SDA) and a clock line
(SCL). The lines are pulled externally to a bus
voltage when they are “idle.” Connected to the
line, a master device generates the SCL signal
and
addresses
and
arranges
the
communication
sequence.
The
MP8846
interface is an I2C slave, which supports both
fast mode (400kHz) and high-speed mode
(3.4Mhz), adding flexibility to the power-supply
solution. The output voltage, transition slew rate,
and other parameters can be controlled
instantaneously by the I2C interface.
Data Validity
One clock pulse is generated for each data bit
transferred. The data on the SDA line must be
stable during the high period of the clock. The
high or low state of the data line can only
change when the clock signal on the SCL line is
low (see Fig. 6).
Data Line
Stable;
Data Valid
Change
of Data
Allowed
SDA
SCL
FIGURE 6. Bit Transfer on the I
2C Bus
Start and Stop Conditions
The start and stop conditions are signaled by
the master device, which signifies the beginning
and the end of the I2C transfer. In the start
condition, the SDA signal transitions from high
to low while the SCL is high. In the stop
condition, the SDA signal transitions from low to
high while the SCL is high (see Fig. 7).
SDA
SCL
P
STOP condition
SDA
SCL
S
START condition
FIGURE 7. Start and Stop Conditions
Start and stop conditions are always generated
by the master. The bus is busy once the start
condition begins; the bus is free again after a
minimum of 4.7us after the stop condition. The
bus stays busy if a repeated start (Sr) is
generated instead of a stop condition. The start
(S) and repeated start (Sr) conditions are
functionally identical.
Transfer Data
Every byte put on the SDA line must be 8 bits
long. Each byte must be followed by an
acknowledge bit. The acknowledge-related
clock pulse is generated by the master. The
transmitter releases the SDA line (high) during
the acknowledge clock pulse. The receiver
must pull down the SDA line during the
acknowledge clock pulse, so that it remains
stable (low) during the high period of the clock
pulse.
Data transfers follow the format shown in Fig. 8.
After the start condition (S), a slave address is
sent. This address is 7 bits long followed by an
8th bit, which is a data direction bit (R/W). A ‘0’
indicates a transmission (write); a ‘1’ indicates a
request for data (read). A data transfer is
terminated always by a stop condition (P)
generated by the master. However, if a master
still wishes to communicate on the bus, it can
generate a repeated start condition (Sr) and
address another slave without first generating a
stop condition.
S
1 7
8
9
1 7
8
9
1 7
8
9
P
STOP
condition
START
condition
DATA
ACK
DATA
ACK
ADDRESS
ACK
R/W
SDA
SCL
FIGURE 8. A Complete Data Transfer
The MP8846 requires a start condition, a valid
I2C address, a register address byte, and a data
byte for a single data update. After receipt of
each byte, the MP8846 acknowledges by
pulling the SDA line low during the high period
of a single clock pulse. A valid I2C address
selects



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com