| Electronic Components Datasheet Search |
|
FNP3000 Datasheet(PDF) 3 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
FNP3000 Datasheet(HTML) 3 Page - Bel Fuse Inc. |
|
3 / 17 page ![]() FNP3000 Series 3 Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2018 Bel Power Solutions & Protection BCD.00669_004 Stanby Output VSB Output Voltage 3.3 VDC Output Current 0 2 A Ripple and Noise 1 33 mVp-p Line and Load Regulation ±5% Vset Load Capacitance 1000 μF Transient Response 50% step load, 1A/ μsec slew rate, recovery to 1% within 1 msec 3 % Vset Startup Time 5 sec 1 Measured at 20 MHz bandwidth at an oscilloscope jack on the output with 0.1 μF ceramic and 10 μF aluminum electrolyitc capacitors. PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Over Voltage Protection V1: latch off V2: latch off 110 60 120 Vdc % Over Current Protection V1: constant current inception V2: hiccup 62.5 2.6 A A Over Temperature Protection at full load, auto recovery 55 °C PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Storage Temperature Non-Condensing -40 70 °C Operating Temperature @ full load no derating 0 50 Humidity Storage Operating Humidity 5 10 90 % MTBF Calculated per Telcordia SR-332 Issue 2, Sept 2006, component stress method at Ta = 25°C 916 Khrs Acoustic ISO 7779-1999 60 dB LpAm Cold 2 IEC 68 Part 2 – 1: at -10°C minimum for 4 hours Dry Heat IEC 68 Part 2 – 2: at 50°C minimum for 4 hours Damp Heat, Cyclic IEC 68 Part 2 – 30: at 20~45°C, 30~95 %RH Low Air Pressure (operating) IEC 68 Part 2 – 13: at 10,000 feet, 697 mbar Vibration (Sinusoidal) IEC 68 Part 2 – 6: at 10~58 Hz, 0.075 mm; 58~500 Hz, 10 m/s2, 1 octave/minute, 10 cycles/main axis 1 G Shock IEC 68 Part 2 – 27: at 300 m/s2, 11 ms, half sine wave 3 shocks / main axis 30 G Bump IEC 68 Part 2 – 29: at 150 m/s2, 6 ms, half sine wave 900 bumps / main axis 15 G WEEE Directive 2012/19/EU RoHS EU Directive 2011/65/EU 2 The module shall start up at -10°C, however it is not required that the full specification is achieved until the operational internal temperature has risen to 0°C. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |