| Electronic Components Datasheet Search |
|
FNP3000 Datasheet(PDF) 4 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
FNP3000 Datasheet(HTML) 4 Page - Bel Fuse Inc. |
|
4 / 17 page ![]() 4 FNP3000 Series tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN TYP MAX UNITS Insulation Safety Rating / Test Voltage Input to output, reinforced input to chassis, basic 3000 1500 Vrms Vrms Isolation Voltage Output to output Output to chassis Signals to chassis/ground V2 to chassis/ground 1500 1500 1500 100 Vrms Vrms VDC VDC Grounding The main output V1 is “floating” and not referenced to chassis/ground.The output control and status signals are referenced to the V2 output return connection. Conducted Emissions FCC 15 Sub Part B, EN55022, Class A: 3dB margin tested with resistive load Radiated Emissions FCC 15 Sub Part B, EN55022, Class A: 3dB margin tested with resistive load Harmonic Compliance EN/IEC 61000-3-2:2009, Class A Harmonic Limits Compliance Level: 230 Vac line voltage; 100% output load Flicker EN/IEC 61000-3-3:2009 limits as specified in the standard: flicker and voltage fluctuations Electrostatic Discharge EN/IEC 61000-4-2, ±8 kV operational air discharge, ±8 kV contact discharge: all parameters to remain within limits, test set up to be defined RF Electro-Magnetic Field. Amplitude Modulated EN/IEC 61000-4-3 80~1000 MHz, 10V/m, 80% AM Modulation (1 kHz): all parameters to remain within limits, test set up to be defined Immunity To Fast Transients EN/IEC 61000-4-4 Power lines: ±2 kV: all parameters to remain within limits, test set up to be defined Surges (Mains) EN/IEC 61000-4-5 ±1 kV line to line, ±2 kV line to earth, Criteria A: all parameters to remain within limits, test set up to be defined RF Continuous Conducted EN/IEC 61000-4-6 150 kHz~80 MHz 3Vrms 80% AM (1 kHz), Criteria A: all parameters to remain within limits, test set up to be defined Voltage Dips/ Interruptions IEC 61000-4-11 30% reduction for 10 ms, 60% reduction for 100 ms: Reset is permitted must be selfrecovering. Additionally, the PSU shall not latch up during any brownout condition. PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Agency Approvals Approved to latest edition of the following standards: UL/CSA60950-1, IEC60950-1 and EN60950-1. PARAMETER DESCRIPTION / CONDITION MIN NOM MAX NIT Dimensions W x H x D 101.6 x 40.6 x 355.6 4 x 1.6 x 14 mm inch Weight 2010 g Cooling / Airflow Integral fans Material Flammability UL 94V-0 AC Input IEC320/C14 DC Output FCI PwrBlade P/N 51939-661LF mates with FCI P/N 51915-351LF |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |