48 / 56 page ![]() Data sheet BMA150 Triaxial, digital acceleration sensor Bosch Sensortec Rev. 1.6 Page 48 30 October 2008 © Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are subject to change without notice. So, the relevant parameters for power consumption in self-wake up mode are: - the current consumption in normal mode - the current consumption in sleep mode - the self-wake up pause duration - the bandwidth (ie. length of digital filter to be filled for one data point) - the interrupt criteria (determines the duration of normal operation): • high-g and low-g criteria (ie. acquisition of one data point) • any-motion criterion (ie. four data points) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|