Back Button ML9352 Datasheet HTML 28Page - OKI electronic componets ML9352 Datasheet HTML 29Page - OKI electronic componets ML9352 Datasheet HTML 30Page - OKI electronic componets ML9352 Datasheet HTML 31Page - OKI electronic componets ML9352 Datasheet HTML 32Page - OKI electronic componets ML9352 Datasheet HTML 33Page - OKI electronic componets ML9352 Datasheet HTML 34Page - OKI electronic componets ML9352 Datasheet HTML 35Page - OKI electronic componets ML9352 Datasheet HTML 36Page - OKI electronic componets Next Button
Zoom Inzoom in Zoom Outzoom out
 32 / 53 page
background image
PEDL9352-01
OKI Semiconductor
ML9352
32/53
• Static ON/OFF (Write)
This is an operation control command of the cathode driver output (COMS1) for static display. When a “1” is
written in bit D0, COMS1 operates and it is possible to carry out the static display. On the other hand, when a “0”
is written in bit D0, COMS1 goes high and the static display is turned off.
Select pin
A0
D7
D6
D5
D4
D3
D2
D1
D0
Static ON
0
1
0
1
0
1
1
0
1
Static OFF
0
1
0
1
0
1
1
0
0
• Power save (Compound command)
The power save mode is entered when the display all-ON command is executed in the display OFF condition. This
mode can greatly reduce the current consumption.
When in the power save mode, the display data and operating mode remain unchanged, and also it is possible to
access the display data RAM from the MPU. The power save mode is released by using the display all-OFF
command.
• Power save mode
When in the power save mode, all operations of the organic EL driving circuit are stopped. When there is no
access from the MPU, the current consumption can be reduced to nearly the static current. The internal circuit
conditions in the power save mode are described below.
(1)
The oscillation circuit stops.
(2)
The voltage regulator stops.
(3)
All the organic EL driving circuits stop and the anode and cathode drivers output the VSS level.
• NOP (Write)
This is a No Operation command.
A0
D7
D6
D5
D4
D3
D2
D1
D0
0
1
1
1
0
0
0
1
1
• Test (Write)
This is a command for testing the IC chip. Do not use this command. When the test command is issued by mistake,
this state can be released by issuing a NOP command. This command will be ineffective if the TEST0 pin is open
or at the “L” level.
A0
D7
D6
D5
D4
D3
D2
D1
D0
0
1
1
1
1
*
*
*
*
*: Invalid bits



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com