Back Button TLE8110ED Datasheet HTML 25Page - Infineon Technologies AG TLE8110ED Datasheet HTML 26Page - Infineon Technologies AG TLE8110ED Datasheet HTML 27Page - Infineon Technologies AG TLE8110ED Datasheet HTML 28Page - Infineon Technologies AG TLE8110ED Datasheet HTML 29Page - Infineon Technologies AG TLE8110ED Datasheet HTML 30Page - Infineon Technologies AG TLE8110ED Datasheet HTML 31Page - Infineon Technologies AG TLE8110ED Datasheet HTML 32Page - Infineon Technologies AG TLE8110ED Datasheet HTML 33Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 74 page
background image
Data Sheet
29
Rev. 1.0
2018-03-07
TLE8110ED
Smart Multichannel Low Side Switch with Parallel Control and SPI Interface
Diagnosis
Refer to Figure 16 for the procedure flow-chart.
8.1.2
Overcurrent / Overtemperature diagnosis
After an OCT assertion the related channel is switched OFF for safety reasons. If an OCT is read out of the
Diagnosis Register, the following procedure is required in order to confirm the channel status and ensure a
safe operation of the device:
After reading the OCT [10B] in the diagnosis register (Chapter 12.3.2 )
1. Set related bit DEVS.DCCx = 0 to disable OFF-diagnosis, see (Chapter 12.3.6),
2. Clear the Diagnosis issuing a DCC.DRxCL command, see (Chapter 12.3.2),
3. Switch-ON for t ≥ tOFFcl_l(max)the related channel,
4. Read again the diagnosis register
a) If OCT is confirmed Then take actions according to system implementation,
5. Set related bit DEVS.DCCx = 1 to enable OFF-diagnosis,
6. Continue normal operation.
Refer to Figure 16 for the procedure flow-chart.
Figure 16
Diagnosis Confirmation procedure
Diagnosis Confirmation
OK
?
SCG
?
take SCG action
yes
no
yes
no
OL
?
yes
no
OCT
?
yes
no
DEVS.DCCx=0
(disable OFF-diag)
DCC.DRxCL
(clear diagnosis)
DCC.DRx
(read Diagnosis)
DEVS.DCCx=1
(enable OFF-diag)
OCT
?
yes
no
take OCT action
take OL action
DCC.DRx
(read diagnosis)
no actions
wait
td(max) with
Channel OFF
OL
?
yes
no
DCC.DRx
(read Diagnosis)
wait
tOFFcl_l(max) with
Channel ON



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com