| Electronic Components Datasheet Search |
|
ADG5401F Datasheet(PDF) 28 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADG5401F Datasheet(HTML) 28 Page - Analog Devices |
|
28 / 31 page ![]() ADG5421F Data Sheet Rev. 0 | Page 28 of 31 APPLICATIONS INFORMATION The ADG5421F overvoltage protected switches provide a robust solution for instrumentation, industrial, aerospace, and other harsh environments where overvoltage signals can be present, and the system must remain operational both during and after an overvoltage occurs. POWER SUPPLY RAILS To guarantee correct operation of the device, 0.1 µF decoupling capacitors are required on both VDD and VSS to GND. The ADG5421F can operate with bipolar supplies between ±5 V and ±22 V. Note that the VDD and VSS supplies do not have to be symmetrical, but the supply range must not exceed 44 V. The ADG5421F can also operate with single supplies between 8 V and 44 V with VSS connected to GND. The ADG5421F is fully specified at the ±15 V, ±20 V, +12 V, and +36 V supply ranges. POWER SUPPLY RECOMMENDATIONS Analog Devices, Inc., has a wide range of power management products to meet the requirements of most high performance signal chains. An example of a bipolar power solution is shown in Figure 50. The ADP5070 (dual switching regulator) generates a positive and negative supply rail for the ADG5421F amplifier and/or a precision converter in a typical signal chain. Also shown in Figure 50 are two optional LDOs, ADP7118 and ADP7182, positive and negative low dropout (LDOs) regulators, respectively, that can be used to reduce the output ripple of the ADP5070 in ultralow noise sensitive applications. ADP7118 LDO +15V ADP7182 LDO –15V +16.5V –16.5V ADP5070 +5V INPUT Figure 50. Bipolar Power Solution Table 11. Recommended Power Management Devices Product Description ADP5070 1 A/0.6 A, dc-to-dc switching regulator with independent positive and negative outputs ADP7118 20 V, 200 mA, low noise, CMOS LDO linear regulator ADP7182 −28 V, −200 mA, low noise, LDO linear regulator POWER SUPPLY SEQUENCING PROTECTION When the ADG5421F is off, the switch channels remain open and signals from −60 V to +60 V can be applied without damaging the device. The switch channels only close when the supplies are connected, a suitable digital control signal is placed on the INx pins, and the signal is within the normal operating range. Note that placing the ADG5421F between external connectors and sensitive components offers protection in systems where a signal is presented to the Sx pins before the supply voltages are available. SIGNAL RANGE The ADG5421F switches have overvoltage detection circuitry on the S1 and S2 pins that compares the voltage levels with VDD and VSS. To protect downstream circuitry from overvoltages, supply the ADG5421F with voltages that match the intended signal range. The NDMOS only architecture used in this switch allows signals up to VDD − 2 V to be passed with little distortion. A signal that exceeds the supply rail by VT is then blocked. This signal block offers protection to both the device and any downstream circuitry. INTELLIGENT FAULT DETECTION The ADG5421F digital output pin (FF) can interface with a microprocessor or control system and be used as an interrupt flag. This feature provides real-time diagnostic information on the state of the device and the system to which the device connects. The control system can use the digital interrupt to start a variety of actions, such as the following: • Initiating investigation into the source of the overvoltage fault • Shutting down critical systems in response to the overvoltage • Data recorders marking data during these events as unreliable or out of specification For systems that are sensitive during a start-up sequence, the active low operation of the flag allows the system to ensure that the ADG5421F powers on and that all input voltages are within the normal operating range before initiating operation. The FF pin is an open drain that requires an external pull-up resistor, which allows signals to be combined into a single interrupt for larger modules that contain multiple devices. SWITCH IN A KNOWN STATE If no digital inputs are present on the switch control lines, INx, the switches remain in an off state to prevent any unwanted signals passing through the switch. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |