201 / 230 page ![]() C-3 TP27, TP37 Equipment Manual Release 01/00 Message Cause Remedy: 026...029 Storage medium not ready, contains errors or status unde- finable. Reset hardware, remove then refit Flash memory module or carry out hardware test. 030 Storage medium not intialized. Switch to download mode. 032 Error accessing module, Flash may not be supported or initialized by incorrect OP. Check whether module is properly inserted and compatible. If restoring: repeat backup with correct OP. 033 Internal Flash memory initialized; configuration data deleted, some recipe data preserved. Retransfer configuration. 034 Inserted module initialized, all stored data deleted. Retransfer configuration. 035 Size of selected recipe memory has been reduced. The reduced-size recipe memory can not be used and all data records must be de- leted. The recipe memory is only initialized when requested. 040 Driver error If FAP is set, the character delay time setting may be too short. Check physical connection with PLC. Modify character delay time. 041 Fault in connection with PLC. Possible causes: – Fault on the transmission link, e.g. connecting cable defective – Incorrect interface parameters set on OP or on com- munication peer. 043 Data transfer error. A variable indicating the cause of the fault is transferred with this message. Variable: 0 Timeout error 1 Framing error (receiving) 2 Overrun error 3 Parity error 4 No connection established 5 Checksum error (receiving) 6 Unexpected characters received 7...11 Internal error 12 Receive data block too large 13 Memory area not available on PLC Repeat the data transfer. Before doing so, check the physical connection/configured interface parameters if necessary. 044 Fault in connection with PLC. Possible causes: – Fault on the transmission link, e.g. connecting cable defective – Incorrect interface parameters set on OP or on com- munication peer. 114 PLC has been restarted. 115 Establishment of logical link with PLC in progress. 117 Connection with PLC is OK again following a fault. 119 Automatic restart. 136 PLC not responding. Check program sequence on PLC. Check physical connection. 138 Data block not available on PLC Set up relevant memory area. System Messages |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |