203 / 230 page ![]() C-5 TP27, TP37 Equipment Manual Release 01/00 Remedy: Cause Message 259 Transfer of a data record to the PLC is taking too long. Example: PLC is not acknowledging data record or very large data records are being transferred. Check PLC program. In the case of large data records no modifications are necessary as the function is being processed correctly. 260 Operating mode of PLC does not match the configura- tion. Change operating mode of PLC. 261 The data in this data record is no longer consistent and it can therefore no longer be used. Edit data record and check that all entries are correct. 262 Password or query window already in use by another function. Complete first function then execute de- sired function again. 263 Specified remaining buffer space for messages has been reached! Configure smaller remaining buffer, delete event/alarm message buffers. 264 Message buffer overflow. The overflow messages are printed out if so specified in the configuration. 265 The number of passwords issued has already reached 50. You can not enter any more passwords. If you wish to issue additional passwords, you must first delete some of the existing ones. 266 The field configured in the PLC job does not exist. Change the parameters of the PLC job and retransfer the configuration. 303 Fault in connection with PLC. S5: this error may occur when transferring large data records. In such cases the watchdog is activated. Check PLC status. S5: set value in data word 98 to at least 2000. 305 Data block number missing. Set up data block or change configuration. 306 Incorrect CPU specified under ”PLC –> Parameters”. Change configuration and retransfer. 307 ... 311 Variable not present on PLC Check configuration of process link. 316 Active password level insufficient for menu item Enter password with higher password level. 339 Startup completed. Communication with PLC has been re- sumed. 340 Status processing in progress on PU/PC. The OP can not be used while this is going on. 341 Internal error With non-Siemens connections: data block error 342 Network node has illegal address. Max. addresses: S7-MPI: 32 PROFIBUS-DP: 128 343 You are attempting to edit a variable of a type that can not be edited in a recipe: currently applies to ARRAY variables only. 350 PLC is performing initialization. You can not enter any setpoints during initialization. Scrolling of screens is possible. This operating mode may be set by the PLC programmer. 351 PLC has completed initialization. You can resume enter- ing setpoints once this message has appeared. System Messages |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |