205 / 230 page ![]() C-7 TP27, TP37 Equipment Manual Release 01/00 Remedy: Cause Message 442 Data block error x DB no. y This message indicates a data block error. The variables x and y identify the cause of the fault ( x)) and the number of the receive block concerned ( y)). Variable x: 0 incorrect block length entered in receive block No. y. 1 incorrect block number entered in receive block No. y . Correct the block length/block number as necessary or send the correct data block. 450 When entering a value, you have attempted to press a key that is not compatible with the defined input field. 451 You have entered a setpoint that is below the configured lower limit. Enter a value that is greater than or equal to the limit. 452 You have entered a setpoint that is above the configured upper limit. Enter a value that is less than or equal to the limit. 453 Time not entered correctly. Enter time correctly 454 Interface parameters incorrectly set, e.g. when specifying parameters for printer interface Enter valid value for interface parameters. The following values are valid: – Baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200 – Data bits: 5,6,7,8 – Stop bits: 1,2 – Timeout: 1...600 455 You have set graphics printing on the OP but the corre- sponding ESC sequence has not been configured. Select a different printer or check printer configuration in ProTool. 456 You have entered an incorrect value, e.g. a variable with a user function that blocks certain input values. Enter permissible value. 458 You have entered a value that is too great or too small for the variable type concerned, e.g. a value greater than 32767 for a variable of the type Integer. Enter a value that is within the permissible range. 459 You are attempting to enter an illegal character (e.g. letter in a numerical value) The input is rejected and the exist- ing entry retained. Enter permissible value. 500...503 Scheduler, counter, date or time data can not be sent. This error can occur if the PLC is tempo- il l d d if h f i bl k i 504 Free ASCII Protocol: operator input value could not be sent. p rarily overloaded or if the function block is not invoked for more than 1.5 s. 505 The data record can not be sent as the recipe disable bit on the PLC is set or because transfer of a recipe is still in progress. Try sending again later when the PLC has released the recipe mailbox. 506 Overload: too many message blocks with the same block number in transit. This error occurs if the PLC sends too many jobs using ’collect message area’ within a certain period of time. 507 Transfer of the data record was not acknowledged by the PLC within a certain period. Checking of data records by the user at the PLC end must be carried out more quickly (< 10 s). 509 Firmware version is different from standard FB version. Please contact the SIMATIC Hotline. System Messages |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |