24 / 44 page ![]() www.ti.com TAS5414 TAS5424 SLOS514 – FEBRUARY 2007 Table 6. Fault Register 2 (0x01) Protection (continued) D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION – – – – – 1 – – Overcurrent shutdown channel 3 has occurred – – – – 1 – – – Overcurrent shutdown channel 4 has occurred – – – 1 – – – – DC offset channel 1 has occurred – – 1 – – – – – DC offset channel 2 has occurred – 1 – – – – – – DC offset channel 3 has occurred 1 – – – – – – – DC offset channel 4 has occurred Table 7. Fault Register 3 (0x02) Load Diagnostics D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 0 0 0 0 0 0 0 No load-diagnostic-created faults, default value – – – – – – – 1 Output short to ground channel 1 has occurred – – – – – – 1 – Output short to PVDD channel 1 has occurred – – – – – 1 – – Shorted load channel 1 has occurred – – – – 1 – – – Open load channel 1 has occurred – – – 1 – – – – Output short to ground channel 2 has occurred – – 1 – – – – – Output short to PVDD channel 2 has occurred – 1 – – – – – – Shorted load channel 2 has occurred 1 – – – – – – – Open load channel 2 has occurred Table 8. Fault Register 4 (0x03) Load Diagnostics D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 0 0 0 0 0 0 0 No load-diagnostic-created faults, default value – – – – – – – 1 Output short to ground channel 3 has occurred – – – – – – 1 – Output short to PVDD channel 3 has occurred – – – – – 1 – – Shorted load channel 3 has occurred – – – – 1 – – – Open load channel 3 has occurred – – – 1 – – – – Output short to ground channel 4 has occurred – – 1 – – – – – Output short to PVDD channel 4 has occurred – 1 – – – – – – Shorted load channel 4 has occurred 1 – – – – – – – Open load channel 4 has occurred Table 9. External Status Register 1 (0x04) Fault Detection D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 0 0 0 0 0 0 0 No protection-created faults are present, default value – – – – – – – 1 PVDD overvoltage fault is present – – – – – – 1 – PVDD undervoltage fault is present – – – – – 1 – – AVDD, analog voltage fault is present – – – – 1 – – – Charge-pump voltage fault is present – – – 1 – – – – Overtemperature shutdown is present – – 1 – – – – – Overtemperature warning – 1 1 – – – – – Overtemperature warning level 1 1 0 1 – – – – – Overtemperature warning level 2 1 1 1 – – – – – Overtemperature warning level 3 24 Submit Documentation Feedback |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |