| Electronic Components Datasheet Search |
|
34704 Datasheet(PDF) 32 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
34704 Datasheet(HTML) 32 Page - Freescale Semiconductor, Inc |
|
32 / 54 page ![]() Analog Integrated Circuit Device Data 32 Freescale Semiconductor 34704 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS Switching frequency for REG6, 7 & 8 FSW2 can be selected to be between 250 kHz and 1.0 MHz in 250 kHz steps. On the 34704B, FSW2 is just for REG8 since REG6 and 7 do not exist in this device. 34704 assigns 2 bits to program FSW2 (FSW2 [1:0]) FSW2 MSB LSB 500kHz (Default) 0 0 250kHz 0 1 750kHz 1 0 1000kHz 1 1 Shutdown Hold (Delay) Time The 34704 assigns 2 bits (SDDELAY[1:0]) for the processor to program the shutdown delay time period Shutdown Delay MSB LSB 1.0sec (Default) 0 0 0.5sec 0 1 1.5sec 1 0 2.0sec 1 1 Please refer to the /ONOFF pin description for more details Programming 34704 response to under-voltage/over- voltage conditions on each regulator There are two responses that can be programmed for an over-voltage/under-voltage condition: Response A : When an over-voltage (under-voltage) event is detected, the concerned output shuts down and a register is flagged to alert the processor. Response B : When an over-voltage/under-voltage event is detected, the concerned output will not shutdown, but the register is flagged to alert the processor. Then, the processor can decide whether to shutdown the output or not. In the mean time, the concerned output control loop will be attempting to correct the error. See Output Over-voltage/Under-voltage Monitoring on page 30 for more details. Response A and Response B share the same flag bit 34704 assigns 1 bit for this function (OVUVSETx) where x corresponds to each regulator. OV/UV Response bit A (Default) 0 B 1 Dynamic Voltage Scaling for each regulator The customer can adjust each regulator’s output dynamically with 2.5% step size. The total range of adjustability will vary depending on each regulator to accommodate different operating environments. Some regulators will utilize the full range of -20.00% to +17.50% and some regulators will only use the range of ±10.00%. For details, see each regulator’s section. Each 2.5% step takes 50 μs before moving to the next step. REG8 only performs DVS when in voltage regulation mode. During DVS, the Over-voltage and Under-voltage monitoring will not be active. In addition to that, these faults will be masked and not active for a DVS settling time period equal to 1ms. This DVS settling time will start after the DVSSTAT register is flagged indicating that the DVS cycle is done. This is to ensure that during DVS and soft start alike the output will not be tripped due to a momentary over- voltage or under-voltage fault. This is the same for Response A and Response B of the over-voltage/under-voltage fault monitoring. 34704 assigns 4 bits register to program the Dynamic Voltage Scaling for each regulator (DVSSETx[3:0]) where x corresponds to each regulator. 2 0 1 REG5 ramps up first Then REG6 and REG7 ramp up together REG5, REG6 and REG7 ramp down together 3 1 0 REG5, REG6, and REG7 ramp up together REG5, REG6, and REG7 ramp down together 4 1 1 REG5 and REG6 ramp up together first. Then ramp up REG7 REG7 ramps down first. Then REG5 and REG6 ramp down together OPTION MSB LSB GRPC/E ENABLED GRPC/E DISABLED |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |