24 / 40 page ![]() AD7714 REV. C –24– The part also offers ZS Self-Calibration and FS Self-Calibration options. In these cases, the part performs just a zero-scale or full-scale calibration respectively and not a full calibration of the part. A full-scale calibration should not be carried out unless the part contains valid zero-scale coefficients. These calibrations are initiated on the AD7714 by writing the appropriate values (1, 1, 0 for ZS Self-Calibration and 1, 1, 1 for FS Self Calibra- tion) to the MD2, MD1 and MD0 bits of the Mode Register. The zero-scale or full-scale calibration is exactly the same as that described for the full self-calibration. In these cases, the duration of the calibration is 3 × 1/Output Rate. At this time the MD2, MD1 and MD0 bits in the Mode Register return to 0, 0, 0. This gives the earliest indication that the calibration sequence is complete. The DRDY line goes high when calibra- tion is initiated and does not return low until there is a valid new word in the data register. The time from the calibration command being issued to DRDY going low is 6 × 1/Output Rate. This is made up of 3 × 1/Output Rate for the zero-scale or full-scale calibration and 3 × 1/Output Rate for a conversion on the analog input. If DRDY is low before (or goes low during) the calibration command write to the Mode Register, it may take up to one modulator cycle (MCLK IN/128) before DRDY goes high to indicate that calibration is in progress. Therefore, DRDY should be ignored for up to one modulator cycle after the last bit of the calibration command is written to the Mode Register. The fact that the self-calibration can be performed as a two step calibration offers another feature. After the sequence of a full self calibration has been completed, additional offset or gain calibrations can be performed by themselves to adjust the part’s zero point or gain. Calibrating one of the parameters, either offset or gain, will not affect the other parameter. System Calibration System calibration allows the AD7714 to compensate for system gain and offset errors as well as its own internal errors. System calibration performs the same slope factor calculations as self- calibration but uses voltage values presented by the system to the AIN inputs for the zero- and full-scale points. Full System calibration requires a two-step process, a ZS System Calibration followed by a FS System Calibration. For a full system calibration, the zero-scale point must be pre- sented to the converter first. It must be applied to the converter before the calibration step is initiated and remain stable until the step is complete. Once the system zero scale has been set up at the analog input, a ZS System Calibration is then initiated by writing the appropriate values (0, 1, 0) to the MD2, MD1 and MD0 bits of the Mode Register. The zero-scale system calibra- tion is performed at the selected gain. The duration of the cali- bration is 3 × 1/Output Rate. At this time, the MD2, MD1 and MD0 bits in the Mode Register return to 0, 0, 0. This gives the earliest indication that the calibration sequence is complete. The DRDY line goes high when calibration is initiated and does not return low until there is a valid new word in the data register. The time from the calibration command being issued to DRDY going low is 4 × 1/Output Rate. This is made up of 3 × 1/Output Rate for the zero-scale system calibration and 1/Output Rate for a conversion on the analog input. This conversion on the analog input is on the same voltage as the zero-scale system calibration and, therefore, the resultant word in the data register from this conversion should be a zero-scale reading. If DRDY is low before (or goes low during) the calibration command write to the Mode Register, it may take up to one modulator cycle (MCLK IN/128) before DRDY goes high to indicate that cali- bration is in progress. Therefore, DRDY should be ignored for up to one modulator cycle after the last bit of the calibration command is written to the Mode Register. After the zero-scale point is calibrated, the full-scale point is applied to AIN and the second step of the calibration process is initiated by again writing the appropriate values (0, 1, 1) to MD2, MD1 and MD0. Again the full-scale voltage must be set up before the calibration is initiated, and it must remain stable throughout the calibration step. The full-scale system calibra- tion is performed at the selected gain. The duration of the cali- bration is 3 × 1/Output Rate. At this time, the MD2, MD1 and MD0 bits in the Mode Register return to 0, 0, 0. This gives the earliest indication that the calibration sequence is complete. The DRDY line goes high when calibration is initiated and does not return low until there is a valid new word in the data register. The time from the calibration command being issued to DRDY going low is 4 × 1/Output Rate. This is made up of 3 × 1/Out- put Rate for the full-scale system calibration and 1/Output Rate for a conversion on the analog input. This conversion on the analog input is on the same voltage as the full-scale system calibration and, therefore, the resultant word in the data register from this conversion should be a full-scale reading. If DRDY is low before (or goes low during) the calibration command write to the Mode Register, it may take up to one modulator cycle (MCLK IN/128) before DRDY goes high to indicate that cali- bration is in progress. Therefore, DRDY should be ignored for up to one modulator cycle after the last bit of the calibration command is written to the Mode Register. In the unipolar mode, the system calibration is performed between the two endpoints of the transfer function; in the bipo- lar mode, it is performed between midscale (zero differential voltage) and positive full scale. The fact that the system calibration is a two step calibration offers another feature. After the sequence of a full system cali- bration has been completed, additional offset or gain calibra- tions can be performed by themselves to adjust the system zero reference point or the system gain. Calibrating one of the parameters, either system offset or system gain, will not affect the other parameter. A full-scale calibration should not be car- ried out unless the part contains valid zero-scale coefficients. System calibration can also be used to remove any errors from source impedances on the analog input when the part is used in unbuffered mode. A simple R, C antialiasing filter on the front end may introduce a gain error on the analog input voltage but the system calibration can be used to remove this error. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |