| Electronic Components Datasheet Search |
|
B-M Datasheet(PDF) 14 Page - General Semiconductor |
|
|
|||||||||||||||||||||||||||||
B-M Datasheet(HTML) 14 Page - General Semiconductor |
|
14 / 20 page ![]() JC030-Series Power Modules: Data Sheet 18 Vdc to 36 Vdc Inputs; 2 Vdc to 15 Vdc Outputs;13 W to 30 W March 26, 2008 14 14 Lineage Power Thermal Considerations (continued) The JC030-Series Power Modules are designed to operate in a variety of thermal environments. As with any electronic component, sufficient cooling must be provided to help ensure reliable operation. Heat-dissi- pating components inside the module are thermally coupled to the case to enable heat removal by conduc- tion, convection, and radiation to the surrounding envi- ronment. The thermal data presented is based on measure- ments taken in a wind tunnel. The test setup shown in Figure 26 was used to collect data for Figures 31 and 32. Note that the natural convection condition was mea- sured at 0.05 ms–1 to 0.1 ms–1 (10 ft./min. to 20 ft./min.); however, systems in which these power modules may be used typically generate natural con- vection airflow rates of 0.3 ms–1 (60 ft./min.) due to other heat dissipating components in the system. The graphs in Figures 27 through 32 provide general guidelines for use. Actual performance can vary depending on the particular application environment. The maximum case temperature of 100 °C must not be exceeded. Basic Thermal Performance The JC030-Series power modules are built with a spe- cially designed, heat spreading enclosure. As a result, full-load operation in natural convection at 50 °C can be achieved without the use of an external heat sink. Higher ambient temperatures can be sustained by increasing the airflow or by adding a heat sink. As stated, this data is based on a maximum case tempera- ture of 100 °C and measured in the test configuration shown in Figure 26. Forced Convection Cooling To determine the necessary airflow, determine the power dissipated by the unit for the particular applica- tion. Figures 27 through 30 show typical power dissipa- tion for those power modules over a range of output currents. With the known power dissipation and a given local ambient temperature, the appropriate airflow can be chosen from the derating curves in Figure 31. For example, if the unit dissipates 6.2 W, the minimum air- flow in an 80 °C environment is 1.02 ms–1 (200 ft./min.). 8-2690(C) Figure 27. JC030D-M Power Dissipation vs. Output Current 8-1154(C) Figure 28. JC030A-M Power Dissipation vs. Output Current 1.6 2.6 3.8 4.6 5.6 0 OUTPUT CURRENT, I O (A) 4 5 7 0.6 1 2 3 VI = 18 V VI = 24 V VI = 36 V 6 6.6 VI = 36 V VI = 27 V VI = 18 V 9 8 7 6 5 4 3 2 1 0 01 2 3 4 56 OUTPUT CURRENT, IO (A) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |