29 / 89 page ![]() ams Datasheet, Confidential:2013-Sep [1-00] AS8506 – 29 Detaile d Desc rip t ion Operating Modes The AS8506 has two main operating modes NORMAL and SLEEP, and has two transition modes WAIT and WAKE. The transition modes are intermediate modes for switching from SLEEP to NORMAL and vice versa. The detailed operation of each mode is explained in subsequent sections. The initialization phase is explained in“Initialization Sequence” on page 36. NORMAL Mode The device enters into NORMAL from WAKE when it receives a short or long trigger. The NORMAL mode is a full functional mode, where all the power supply and analog blocks are in ON-state and the digital is fully functional. The NORMAL mode has two phases of operation: • Diagnosis phase • Balance phase Diagnosis Phase In Diagnosis phase AS8506 detects the number of cells connected to the device. The connected cell voltages are then compared with upper & lower thresholds and target cell voltage of all cells connected. Upper and lower cell voltage thresholds as well as target cell voltages are provided from external in analog or digital format. The Diagnosis phase sequence of operation is explained below. • Detects number of cells connected to the device by comparing each cell terminals to cell detect threshold voltage. • Simultaneously compares each connected cell voltage with set lower operating voltage threshold Vlimit_L. If any of the cell voltages is less than the set lower operating threshold, then an indication is given on CVT_NOK_OUT pin stating that one/more cell voltages are not within the operating voltage threshold range. Each cell status is stored in cel_low_thsld_stat_reg register. • Simultaneously compares each connected cell voltage with set higher operating voltage threshold Vlimit_H. If any of the cell voltages is greater than the set higher operating threshold, then an indication is given on CVT_NOK_OUT pin stating that one/more cell voltages are not within the operating voltage threshold range. Each cell status is stored in cel_high_thsld_stat_reg register. • Simultaneously compares each connected cell voltage with reference value. This result is stored in cel_ref_stat_reg register and used in balance phase. Cell reference can be provided by microcontroller by writing into register or by providing input at external pin VREF_IN. • Enables the SAR ADC and measures each cell voltage and two temperature inputs sequentially. The 12 bits cell voltage and temperature inputs information is stored in respective registers. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |