31 / 36 page ![]() AN2640 Board description 31/36 6.3.2 PF, THD and ballast efficiency The power factor, total harmonic distortion of current and ballast efficiency are measured and the results are shown in Table 4, 5, 6, and 7. 6.3.3 Electromagnetic compatibility The EMC tests have been performed according to the EN55015 standard (Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment). The Agilent E7401A EMC Analyzer has been used as test equipment. Table 4. 24 W lamp power Mains PF THD η% 185 V at 50 Hz 0.968 17.6 88.2 230 V at 50 Hz 0.949 20.0 89.3 265 V at 50 Hz 0.923 22.0 89.9 Table 5. 39 W lamp power Mains PF THD η% 185 V at 50 Hz 0.983 13.5 90.4 230 V at 50 Hz 0.970 15.7 90.6 265 V at 50 Hz 0.956 17.4 90.6 Table 6. 54 W lamp power Mains PF THD η% 185 V at 50 Hz 0.989 11.3 94.1 230 V at 50 Hz 0.982 13.0 94.4 265 V at 50 Hz 0.972 14.4 94.6 Table 7. 80 W lamp power Mains PF THD η% 185 V at 50 Hz 0.992 10.9 97.6 230 V at 50 Hz 0.988 11.1 98.0 265 V at 50 Hz 0.980 14.6 98.2 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |