| Electronic Components Datasheet Search |
|
AP4201 Datasheet(PDF) 22 Page - Asahi Kasei Microsystems |
|
|
|||||||||||||||||||||||||||||
AP4201 Datasheet(HTML) 22 Page - Asahi Kasei Microsystems |
|
22 / 27 page ![]() [AP4201] 015008157-E-00 - 22 - 2015/09 8V~24V VIN VDC2 内蔵POR VINRST リセット リセット解除中 1.8V VDC2RST Figure 7. POR Timing Chart Table 13. POR Timing when VIN Decreases Parameter min typ max Unit Condition VINrst - 4.0 4.2 V VIN reset voltage VDC2rst - 1.2 1.5 V Internal 1.8V LDO reset voltage (reference value) Note 19. This function executes reset when the supply voltage decreases, preventing instability. However, the reset may not be executed even the supply voltage becomes below the VINrst voltage such as when VIN decreases to near 0V instantaneously. Therefore, in the actual use, it is recommended to design the application in consideration with the VIN voltage to avoid activating this function by peripheral noise or voltage fluctuations. Note 20. The IC is designed to work normally as possible, so sometimes LED gradation data can be hold even when VIN< VINRST, and LEDs turn off all at once. (Lighting setting is holding) Note 21. As long as the VIN voltage (IC pin voltage) is more than the maximum VINrst voltage, continuous proper operation of the AP4201 is guaranteed (by design). However if the VIN voltage is out of recommend voltage range, the communication function via input signal is not guaranteed. 10.7. Reset State Immediately after start up the AP4201 or after reset by decreasing power supply voltage, LED gradation data in the IC is all reset (all data= “0”). Therefore, LEDs will not light unless new gradation data is input via SCI interface. The AP4201 has all turn off function (in case of SCI interface control). It can be used as reset function. Reset types and reset states are shown below. Table 14. Types of Reset and status Types of Reset VIN Input VIN falls VDC1 falls VDC2 falls LED All Off LED lighting status LED All Off LED gradation data input Impossible Possible LED gradation data hold - Hold Hold Reset Hold LDO1(5V) Output Undefined Normal Internal POP Reset release Reset |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |