| Electronic Components Datasheet Search |
|
ATS675 Datasheet(PDF) 11 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
ATS675 Datasheet(HTML) 11 Page - Allegro MicroSystems |
|
11 / 14 page ![]() Self-Calibrating TPOS Speed Sensor IC Optimized for Automotive Cam Sensing Applications ATS675LSE 11 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com AGC is activated during the Initial Calibration stage at each power-on. The device measures the peak-to-peak application magnetic gradient, and then the gain of the sensor IC is adjusted to normalize the internal processed signal, VPROC, to accommo- date any input signal amplitude within the specified Operating Magnetic Signal Range, BSIG. AGC is referenced to the internal magnetic baseline. At the end of the Initial Calibration stage, the AGC results are latched and they are not readjusted while the device remains powered-on. Power Supply Protection The ATS675 provides features for protecting the device against power supply aberrations: Undervoltage Lockout When the supply voltage falls below the undervoltage lockout level, VCCUV, the device Output State changes to Off. The device remains in that state until the volt- age level is restored to the VCC operating range. Changes in the target magnetic gradient have no effect until that voltage level is restored. This prevents false signals caused by undervoltage conditions from propagating to the output of the sensor IC. EMC Protection The ATS675 contains an on-chip regulator that operates throughout a wide range of supply voltage levels. For applications using an unregulated power supply, protection against transients may be added externally. For applications using a regulated supply line, EMI and RFI protection may still be required. Contact Allegro for information on EMC specification compliance. Operating Modes The device provides three operating modes: TPOS, Calibration, and Running. TPOS and Calibration initialize simultaneously at power-on. TPOS generates immediate device output, controlling device switching while the calibration functions are performed. After calibration is complete, normal operation in Running mode begins. TPOS (True Power-On State) Operation After the power-on time, tPO, the device immediately generates an output voltage corresponding to the target feature opposite the device. It does so by comparing the existing level of the appli- cation magnetic gradient, BAPP , to the TPOS switching level, an internal threshold used to distinguish a tooth from a valley during TPOS operation (from power-on until the end of the Initial Calibration stage). If BAPP is less than the threshold, that target feature is evaluated as a valley, and if BAPP is greater , the feature is evaluated as a tooth. Calibration Mode Operation At power-on (simultaneous with TPOS operation) Calibration mode begins. Calibration mode is performed in two stages: the Initial Calibration stage, followed immediately by the TPOS to Running Mode Transition stage (see figure 7). After the second calibration stage, Running mode begins immediately. In Calibration mode, the operating range of the application magnetic gradient, BAPP, is detected and evaluated, and then the ATS675 electronics are adapted for optimal output switching. Calibration is performed quickly, without reading the entire tar- get, because the ATS675 applies the internal magnetic baseline. Initial Calibration Stage During the Initial Calibration stage, TPOS operation controls device output switching while calibra- tion starts. In this stage, the peak-detecting DACs acquire the application magnetic signal. Based on those results, the Auto- matic Gain Control (AGC) feature calculates the normalized Running mode switching range. This period is minimized, so swapping to the Running mode thresholds can occur as quickly as possible. TPOS to Running Mode Transition Stage At the beginning of this stage, TPOS operation terminates, and throughout this stage the device automatically adjusts the output switching levels from the original preset switching level to the Running mode switchpoints. This transition takes place over one tooth, immedi- ately swapping from TPOS to Running mode switchpoints. Figure 7. Calibration mode waveforms. Time Running mode switchpoints for I option TPOS switching level On Output State for HT option Off On Off On Off CALI CALTPOSRM Running Mode |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |