| Electronic Components Datasheet Search |
|
86115D2 Datasheet(PDF) 23 Page - Keysight Technologies |
|
|
|||||||||||||||||||||||||||||
86115D2 Datasheet(HTML) 23 Page - Keysight Technologies |
|
23 / 37 page ![]() 23 | Keysight | Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet Clock recovery modules 83496B-100 83496B-101 Channel type Differential or single-ended electrical Single-mode or multimode optical, differential or single-ended electrical (no internal electrical splitters) Data rates (divide by 2 for clock signals) Standard: 50 Mb/s to 7.1 Gb/s continuous tuning Option 200: 50 Mb/s to 14.2 Gb/s continuous tuning Option 201: 7.1 to 14.2 Gb/s continuous tuning For rates above 14 Gb/s, the N1076A and N1077A operate from 50 Mb/s to 32 Gb/s Minimum input level to acquire lock (voltage or OMA 1) 150 m Vpp Single-mode (OMA 1): –11 dBm to 50 Mb/s to 11.4 Gb/s –8 dBm to > 11.4 Gb/s –12 dBm to 7.1 to 14.2 Gb/s (with Option 200) –14 dBm to 1 to 7.1 Gb/s –15 dBm to 50 Mb/s to 1 Gb/s Multimode 1310 nm (OMA 1): –10 dBm to 50 Mb/s to 11.4 Gb/s –7 dBm to > 11.4 Gb/s –11 dBm to 7.1 to 14.2 Gb/s (with Option 200) –13 dBm to 1 to 7.1 Gb/s –14 dBm to 50 Mb/s to 1 Gb/s Multimode 850 nm (OMA 1): –8 dBm to 50 Mb/s to 11.4 Gb/s –7 dBm to > 11.4 Gb/s –9 dBm to 7.1 to 14.2 Gb/s (with Option 200) –11 dBm to 1 to 7.1 Gb/s –12 dBm to 50 Mb/s to 1 Gb/s Electrical: 150 m Vpp Output random jitter (RMS) 2 Internal recovered clock trigger: < 500 fs 7.2 to 11.4 Gb/s (300 fs to 10 Gb/s) < 700 fs 4.2 to 7.2 Gb/s, 11.4 Gb/s to 14.2 Gb/s (400 fs to 4.25 Gb/s, 500 fs to 2.5 Gb/s) < 3 mUI 50 Mb/s to 4.2 Gb/s (700 fs to 1.25 Gb/s) Front panel recovered clock: < 700 fs 7.2 to 11.4 Gb/s (300 fs to 10 Gb/s) < 900 fs 4.2 to 7.2 Gb/s, 11.4 to 14.2 Gb/s (400 fs to 4.25 Gb/s, 500 fs to 2.5 Gb/s) < 4 mUI 50 Mb/s to 4.2 Gb/s (700 fs to 1.25 Gb/s) Clock recovery adjustable loop bandwidth range (user selectable) Standard: 270 kHz or 1.5 MHz 3 Option 300: 15 kHz to 10 MHz 4 continuous tuning (fixed value or a constant rate/N ratio) Loop bandwidth accuracy Standard: ± 30% Option 300: ± 25% for transition density = 0.5 and data rate 155 Mb/s to 11.4 Gb/s (± 30% for 0.25 ≤ transition density ≤ 1.0 and all data rates) Tracking range ± 2500 ppm, 83496B ± 1000 ppm, 83496A Aquisition range ± 5000 ppm Internal splitter ratio 50/50 50/50 single-mode 30/70 multimode Electrical signals have input only (no internal power dividers) Input return loss 22 dB (DC to 12 GHz) electrical 20 dB single-mode, 16 dB multimode 16 dB (12 to 20 GHz) electrical 22 dB min (DC to 12 GHz) electrical 16 dB min (12 to 20 GHz) electrical Input insertion loss 7.2 dB max (DC to 12 GHz) electrical 4 dB max single-mode optical 7.8 dB max (12 to 20 GHz) electrical 4 dB max multimode optical (no electrical data output signal path) See footnotes on next page. Modules Specifications (Continued) Clock recovery The DCA platform offers clock recovery capability in the form of DCA plug-in modules such as the 83496B or standalone clock recovery solutions such as the N1076A/N1077A. Specifications for 83496B modules are summarized below. For more information on standalone clock recovery solutions, please download the N1076A/N1077A data sheet from www.keysight.com/find/N1077A. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |