| Electronic Components Datasheet Search |
|
MCP39F511 Datasheet(PDF) 36 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP39F511 Datasheet(HTML) 36 Page - Microchip Technology |
|
36 / 62 page ![]() MCP39F511 DS20005393B-page 36 2015 Microchip Technology Inc. bit 12 ZCD_INV: Zero Crossing Detection Output Inverse 1 = ZCD is inverted 0 = ZCD is not inverted (Default) bit 11 ZCD_PULS: Zero Crossing Detection Pulse mode 1 = ZCD output is 100 µs pulses on zero crossings 0 = ZCD Output changes logic state on zero crossings (Default) bit 10 ZCD_OUTPUT_DIS: Disable the Zero Crossing output pin 1 = ZCD output is disabled 0 = ZCD output is enabled (Default) bit 9 Unimplemented: Read as ‘0’ bit 8 SINGLE_WIRE: Single-Wire Enable bit 1 = Single-wire transmission is enabled 0 = Single-wire transmission is disabled (Default) bit 7 TEMPCOMP: Temperature-Compensation Enable bit 1 = Temperature compensation is enabled 0 = Temperature compensation is disabled (Default) bit 6-5 RESET <1:0>: Reset mode setting for ADCs 11 = Both I1 and V1 are in Reset mode 10 = V1 ADC is in Reset mode 01 = I1 ADC is in Reset mode 00 = Neither ADC is in Reset mode (Default) bit 4-3 SHUTDOWN <1:0>: Shutdown mode setting for ADCs 11 = Both I1 and V1 are in Shutdown 10 = V1 ADC is in Shutdown 01 = I1 ADC is in Shutdown 00 = Neither ADC is in Shutdown (Default) bit 2 VREFEXT: Internal Voltage Reference Shutdown Control 1 = Internal Voltage Reference Disabled 0 = Internal Voltage Reference Enabled (Default) bit 1-0 Unimplemented: Read as ‘0’ Note 1: The UART Baud Rate bits are only available on system version 0xFA14 and later. Previous versions have the baud rate fixed at 115200. The baud rate is only changed at system power-up, so a Save To Flash command is required after changing the baud rate. REGISTER 6-3: ENERGY ACCUMULATION CONTROL REGISTER U-0 U-0 U-0 U-0 U-0 U-0 U-0 U-0 — — — — — — — — bit 15 bit 8 U-0 U-0 U-0 U-0 U-0 U-0 U-0 R/W-0 — — — — — — — ENRG_CNTRL bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bits 15-1 Unimplemented: Read as ‘0‘ bit 0 ENRG_CNTRL: Energy Accumulation Control bit 1 = Energy is ON and all registers are accumulating 0 = Energy accumulation is turned off and all energy accumulation registers are reset to 0 (Default) REGISTER 6-2: SYSTEM CONFIGURATION REGISTER (CONTINUED) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |