| Electronic Components Datasheet Search |
|
XT40.481 Datasheet(PDF) 3 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
XT40.481 Datasheet(HTML) 3 Page - PULS GmbH |
|
3 / 20 page ![]() XT40.481, XT40.482 – X-Series 48V, 20A, THREE-PHASE INPUT Jan. 2007 / Rev. 1.0 DS-XT40.48x-EN All parameters are specified at 48V 20A, 3x400Vac (XT40.481) or 3x480Vac (XT40.482), 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 3/20 5. AC-INPUT XT40.481 XT40.482 AC input nom. 3AC 400V 3AC 480V Mains arrangement TN-, TT- or IT-Mains consult factory if one phase is earthed AC input range min. 3x 360-440Vac 3x 432-528Vac fully regulated output (±2%), Pout > 48W min. 3x 300-460Vac *) 3x 360-552Vac *) permanently allowed, see Fig. 5-1 for output voltage regulation max. 3x 475Vac 3x 565Vac Absolute maximum input voltage with no damage to the power supply. Output might be off at this level. Input frequency nom. 50 – 60Hz 50 – 60Hz ±6% Turn-on voltage typ. 3x 325Vac 3x 390Vac see Fig. 5-2 Shut-down voltage typ. 3x 295Vac 3x 355Vac see Fig. 5-2 Input current nom. 1.65A 1.4A at 20A, symmetrical input, see Fig. 5-4 Power factor **) typ. 0.93 0.93 at 20A, symmetrical input, see Fig. 5-5 Turn-on overshoot typ. 1000mV 1000mV see Fig. 5-3 Start-up delay ***) typ. 400ms 350ms over the entire load range, see Fig. 5-3 Rise time typ. 40ms 40ms 0mF, 20A, see Fig. 5-3 typ. 70ms 70ms 20mF, 20A, see Fig. 5-3 *) A minimum voltage of 3x340Vac (XT40.481) or 3x408Vac (XT40.482) is required to turn the power supply on. **) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit. ***) The start-up delay for mains voltage interruptions up to 350ms is close to zero. In such cases, the power supply will immediately generate the output voltage once the mains voltage interruption is over. Do not use the buffer module UF20.481 as an accessory when longer mains interruptions need to be bridged (see chapter 24). Input Voltage Range Fig. 5-1 Output voltage vs. input voltage and input current Changes of the input voltage will be fully regulated within certain limits. The output voltage will only start to change proportionally to the input voltage with extreme under or over-voltages. The yellow LED reports an input voltage problem if exceeded by a window of ±15%. The maximum increase of the output voltage is limited to the 57.2V OVP level. This level will be kept regulated for 2s before the power supply will shut down and reports “Shut-down” by the red LED. 48V 40V 52V 44V 420 340 480Vac 320 504 456 576Vac 384 XT40.481: VOUT VIN XT40.482: 400 360 380 440 480 460 300 56V 528 552 432 408 360 POUT > 48W (>5%) POUT = 0W |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |