| Electronic Components Datasheet Search |
|
XRT75R03D Datasheet(PDF) 5 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
XRT75R03D Datasheet(HTML) 5 Page - Exar Corporation |
|
5 / 134 page ![]() XRT75R03D THREE CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT WITH SONET DESYNCRONIZER REV. 1.0.2 II Figure 15. B3ZS Encoding Format ................................................................................................................. 42 Figure 16. HDB3 Encoding Format ................................................................................................................ 42 5.3 TRANSMIT PULSE SHAPER: .............................................................................................................................. 43 5.3.1 Guidelines for using Transmit Build Out Circuit: ........................................................................... 43 5.3.2 Interfacing to the line: ....................................................................................................................... 43 5.4 TRANSMIT DRIVE MONITOR: ............................................................................................................................. 44 5.5 TRANSMITTER SECTION ON/OFF: ...................................................................................................................... 44 6.0 The Receiver Section: ...................................................................................................................... 44 6.1 AGC/EQUALIZER: ............................................................................................................................................ 44 Figure 17. Transmit Driver Monitor set-up. ..................................................................................................... 44 6.1.1 Interference Tolerance: ..................................................................................................................... 45 Figure 18. Interference Margin Test Set up for DS3/STS-1 ........................................................................... 45 6.2 CLOCK AND DATA RECOVERY: ......................................................................................................................... 46 Figure 19. Interference Margin Test Set up for E3. ........................................................................................ 46 TABLE 9: INTERFERENCE MARGIN TEST RESULTS .............................................................................................. 46 6.3 B3ZS/HDB3 DECODER: .................................................................................................................................. 47 6.4 LOS (LOSS OF SIGNAL) DETECTOR: ................................................................................................................ 47 6.4.1 DS3/STS-1 LOS Condition: ................................................................................................................ 47 DISABLING ALOS/DLOS DETECTION: ......................................................................................................... 47 6.4.2 E3 LOS Condition: ............................................................................................................................. 47 TABLE 10: THE ALOS (ANALOG LOS) DECLARATION AND CLEARANCE THRESHOLDS FOR A GIVEN SETTING OF LOSTHR AND REQEN (DS3 AND STS-1 APPLICATIONS) ................................................................... 47 Figure 20. Loss Of Signal Definition for E3 as per ITU-T G.775 .................................................................... 48 Figure 21. Loss of Signal Definition for E3 as per ITU-T G.775. .................................................................... 48 6.4.3 Muting the Recovered Data with LOS condition: ............................................................................ 49 7.0 Jitter: ................................................................................................................................................. 49 7.1 JITTER TOLERANCE - RECEIVER: ...................................................................................................................... 49 7.1.1 DS3/STS-1 Jitter Tolerance Requirements: ..................................................................................... 49 Figure 22. Jitter Tolerance Measurements ..................................................................................................... 49 7.1.2 E3 Jitter Tolerance Requirements: ................................................................................................... 50 Figure 23. Input Jitter Tolerance For DS3/STS-1 .......................................................................................... 50 Figure 24. Input Jitter Tolerance for E3 ......................................................................................................... 50 7.2 JITTER TRANSFER - RECEIVER/TRANSMITTER: .................................................................................................. 51 7.3 JITTER ATTENUATOR: ...................................................................................................................................... 51 TABLE 11: JITTER AMPLITUDE VERSUS MODULATION FREQUENCY (JITTER TOLERANCE) ..................................... 51 TABLE 12: JITTER TRANSFER SPECIFICATION/REFERENCES ............................................................................... 51 7.3.1 Jitter Generation: ............................................................................................................................... 52 8.0 Serial Host interface: ....................................................................................................................... 52 TABLE 13: JITTER TRANSFER PASS MASKS ....................................................................................................... 52 Figure 25. Jitter Transfer Requirements and Jitter Attenuator Performance .................................................. 52 TABLE 14: FUNCTIONS OF SHARED PINS ............................................................................................................ 53 TABLE 15: XRT75R03D REGISTER MAP - QUICK LOOK .................................................................................... 54 ................................................................................................................................................................. 56 THE REGISTER MAP AND DESCRIPTION FOR THE XRT75R03D 3-CHANNEL DS3/E3/STS-1 LIU IC . 56 Legend: .................................................................................................................................................................. 56 TABLE 16: COMMAND REGISTER ADDRESS MAP, WITHIN THE XRT75R03D 3-CHANNEL DS3/E3/STS-1 LIU W/ JITTER ATTENUATOR IC ................................................................................................................................. 56 THE GLOBAL/CHIP-LEVEL REGISTERS ............................................................................................... 58 ................................................................................................................................................................. 58 REGISTER DESCRIPTION - GLOBAL REGISTERS .............................................................................. 58 TABLE 17: LIST AND ADDRESS LOCATIONS OF GLOBAL REGISTERS .................................................................... 58 TABLE 18: APS/REDUNDANCY CONTROL REGISTER - CR0 (ADDRESS LOCATION = 0X00) .................................. 58 TABLE 19: BLOCK LEVEL INTERRUPT ENABLE REGISTER - CR32 (ADDRESS LOCATION = 0X20) ......................... 61 TABLE 20: BLOCK LEVEL INTERRUPT STATUS REGISTER - CR33 (ADDRESS LOCATION = 0X21) ......................... 62 TABLE 21: DEVICE/PART NUMBER REGISTER - CR62 (ADDRESS LOCATION = 0X3E) .......................................... 63 ................................................................................................................................................................. 64 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |