| Electronic Components Datasheet Search |
|
IMX35 Datasheet(PDF) 13 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
IMX35 Datasheet(HTML) 13 Page - Bel Fuse Inc. |
|
13 / 16 page ![]() tech.support@psbel.com belfuse.com/power-solutions BCD20009-G Rev F, 20-Nov-2020 Page 13 of 16 IMX35 Series 35 Watt Quad-Output DC-DC Converter © 2020 Bel Power Solutions & Protection Immunity to Environmental Conditions Table 12: Mechanical and climatic stress Test method Standard Test Conditions Status Cab Damp heat steady state IEC/EN 60068-2-78 MIL-STD-810D section 507.2 Temperature: 40 ±2 °C Converter not operating Relative humidity: 93 +2/-3 % Duration: 56 days Ka Salt mist test (sodium chloride NaCl solution) 2 EN 50155:2007 clause 12.2.10 class ST3 2 Temperature: 35 ±2 °C Converter not operating Duration: 48 h Fc Vibration (sinusoidal) IEC/EN 60068-2-6 MIL-STD-810D section 514.3 Acceleration amplitude: 0.35 mm (10 – 60 Hz) 5 g n = 49 m/s 2 (60 - 2000 Hz) Converter operating Frequency (1 Oct/min): 10 – 2000 Hz Test duration: 7.5 h (2.5 h in each axis) Fh Random vibration road-band (digital control) & guidance IIEC/EN 60068-2-64 Acceleration spectral density: 0.05 g n 2 /Hz Converter operating Frequency band: 8 to 500 Hz Acceleration magnitude: 4.9 g n rms Test duration: 1.5 h (0.5 h in each axis) Ea Shock (half-sinusoidal) IEC/EN 60068-2-27 MIL-STD-810D section 516.3 Acceleration amplitude: 50 g n = 490 m/s 2 Converter operating Bump duration: 11 ms Number of bumps: 18 (3 in each direction) - Shock EN 50155:2007 clause 12.2.11 EN 61373 sect. 10, class B, body mounted 1 Acceleration amplitude: 5.1 g n Converter operating Bump duration: 30 ms Number of bumps: 18 (3 in each direction) - Simulated long life testing at increased random vibration levels EN 50155:2007 clause 12.2.11 EN 61373 sect. 8 and 9, body mounted 1 Acceleration spectral density: 0.02 g n 2 /Hz Frequency band: 5 to 150 Hz Converter operating Acceleration magnitude: 0.8 g n rms Test duration: 15 h (5 h in each axis) 1 Body mounted = chassis of a railway coach 2 Models without option Z Temperatures Table 13: Temperature specifications, valid for air pressure of 800 to 1200 hPa (800 to 1200 mbar) Model -8 Unit Characteristics Conditions min typ max T A Ambient temperature Operational 1 - 40 3 85 1 °C T C Case temperature (without opt. Z) 2 - 40 3 105 2 T C Z Components temperature with opt. Z 2 - 40 3 105 2 T S Storage temperature Non operational - 55 85 1 See Thermal Considerations 2 Temperature measurement point; see Mechanical Data 3 Start-up at –55 °C Reliability Table 14: MTBF at nom. load Ratings Ground benign Ground fixed Ground mobile Device hours 1 Unit Model Standard 40 °C 40 °C 70 °C 50 °C 40IMX35 MIL-HDBK-217F, T C 336 000 141 000 86 000 110 000 396 000 h 110IMX35 Bellcore, T A 1 445 000 529 000 294 000 144 000 1 The device hours are based upon the IMX35 series field failure rate recorded between 2000 and 2005 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |