Back Button LT3757 Datasheet HTML 16Page - Analog Devices LT3757 Datasheet HTML 17Page - Analog Devices LT3757 Datasheet HTML 18Page - Analog Devices LT3757 Datasheet HTML 19Page - Analog Devices LT3757 Datasheet HTML 20Page - Analog Devices LT3757 Datasheet HTML 21Page - Analog Devices LT3757 Datasheet HTML 22Page - Analog Devices LT3757 Datasheet HTML 23Page - Analog Devices LT3757 Datasheet HTML 24Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 48 page
background image
LTC7841
20
Rev. 0
For more information www.analog.com
OPERATION
Internal Reference DAC
The LTC7841 has an internal 9-bit DAC that allows the
internal reference voltage to be set to any value in the
range of 0 to 2.4V with 0.2%/bit resolution. The digital
value is changed with the MFR_VOUT_COMMAND com-
mand through the PMBus interface. When a change in
the reference is detected, the reference is ramped (0.2%/
step) from its current value to the new value at a rate set
by the capacitor value connected to the CSLEW pin. The
slew rate can also be changed by the PMBus interface
using the MFR_CONFIG command. Using this command,
the slew rate can be set to one of three relative values:
nominal (1x), fast (2x) and slow (0.125x). The LTC7841
can be pre-loaded with two additional reference values
with the MFR_VOUT_MARGIN_HIGH and MFR_VOUT_
MARGIN_LOW commands. Once loaded, the reference
can then be switched between any of these three reg-
ister values by setting the appropriate margin bit in the
OPERATION register.
Whenever a power cycle, RUN pin turn-on, or MFR_RESET
event occurs, the MFR_VOUT_COMMAND register will be
re-initialized to zero. Margin high/low registers are also
initialized to zero at this time.
During VOUT changes, PLLIN/MODE pin setting is ignored
and forced continuous mode is used to guarantee that
VOUT is changed at the programmed slew rate regardless
of the load.
Telemetry Readback
The LTC7841 has an integrated 13-bit ADC that monitors
and performs conversions on the input and output volt-
age, input and output current, and either die temperature
or remote sense temperature. The values are refreshed
at a 25Hz rate and are readable through the PMBus inter-
face. A peak monitor is also available for each of these
telemetry measurements to provide that highest value
measured since the start of the monitor. The monitor is
reset by the MFR_CLEAR_PEAKS command, writing to
the individual peak register, or cycling the RUN pin.
Temperature Monitor and Thermal Warning/Shutdown
The LTC7841 has two internal die temperature monitors
— one that is digitized by the ADC and reported with
the READ_TEMPERATURE_1 command and a second
that is used to shut down the LTC7841 IC when the die
temperature exceeds 170°C. A third temperature moni-
tor is also available for external temperature sensing by
connecting an external temperature sense element to the
TSNS pin. This is useful for monitoring temperature close
to the power inductor or power MOSFETs where tem-
perature is typically highest. The LTC7841 reports either
internal die temperature or external temperature sense
voltage with the READ_TEMPERATURE_1 command. The
MFR_CONFIG register is used to set which one is active.
When internal die temperature is selected and the inter-
nal die temperature exceeds 150°C, the overtemperature
warning bit in the STATUS_WORD is set and the ALERT
pin pulls low to alert the PMBus master. This overtem-
perature warning bit is latched and remains set until the
host clears it. Both internal die temperature monitors have
about 20°C of hysteresis before the overtemperature con-
dition is cleared.
SERIAL INTERFACE
The LTC7841 serial interface is a PMBus compliant slave
device and can operate at any frequency between 10kHz
and 400kHz. The address is configurable using an external
resistor. In addition the LTC7841 always responds to the
global broadcast address of 0x5A or 0x5B (7 bit). The
serial interface supports the following protocols defined
in the PMBus specifications: 1) send command, 2) write
byte, 3) write word, 4) group, 5) read byte and 6) read
word. The PMBus write operations are not acted upon
until a complete valid message is received by the LTC7841
including the STOP bit.
Communication Failure
Attempts to access unsupported commands or writing
invalid data to supported commands will result in a CML
fault. The CML bit is set in the STATUS_WORD command
and the ALERT pin is pulled low.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com