LT3045 Datasheet(PDF) 55 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LT3045 Datasheet(HTML) 55 Page - Analog Devices |
|
55 / 62 page ![]() Data Sheet LT3074 analog.com Rev 0. 55 of 62 MFR_BIAS_UV_WARN_LIMIT The MFR_BIAS_UV_WARN_LIMIT command sets the value of the bias voltage measured at the BIAS pin, in Volts, which causes a bias voltage low warning. The bias voltage measured and converted by the ADC (and reported using the MFR_READ_VBIAS command) is used to compare the actual bias voltage to the limit value. As a result, there can be up to a 20ms delay from the time the bias voltage hits the limit to the time the fault is reported. Transitionary faults that last for a time period smaller than the ADC conversion time are filtered out and not reported. In response to the MFR_BIAS_UV_WARN_LIMIT being exceeded, the device: Sets the NONE_OF_THE_ABOVE bit in STATUS_BYTE register. Sets the MFRSPECIFIC bit in the STATUS_WORD register. Sets the VBIAS_UV_WARNING bit in the STATUS_MFR_SPECIFIC register. Notifies the host by asserting the ALERT pin. This command has two data bytes and is formatted in the Linear_5s_11s format. MFR_IOUT_MIN_WARN_LIMIT The MFR_IOUT_MIN_WARN_LIMIT command sets the value of the minimum output current, in Amperes, which causes an output low current warning. This command can be used to detect open connections from the output of the LT3074 to the load device. The output current measured and converted by the ADC (and reported using the READ_IOUT command) is used to compare the actual output current to the limit value. As a result, there can be up to a 14ms delay from the time the output current hits the limit to the time the fault is reported. Transitionary faults that last for a time period smaller than the ADC conversion time are filtered out and not reported. In response to the MFR_IOUT_MIN_WARN_LIMIT being exceeded, the device: Sets the NONE_OF_THE_ABOVE bit in STATUS_BYTE register. Sets the MFRSPECIFIC bit in the STATUS_WORD register. Sets the IOUT_MIN_WARNING bit in the STATUS_MFR_SPECIFIC register. Notifies the host by asserting the ALERT pin. This command has two data bytes and is formatted in the Linear_5s_11s format. If the LT3074 is powered on without a preload greater than the default value set by MFR_MIN_IOUT_WARN_LIMIT register, the LT3074 asserts a fault once it completes the start-up procedure. MFR_SPECIAL_ID The MFR_SPECIAL_ID command is used by the LTPowerPlay GUI for device identification. This read-only command has two data bytes. MFR_DEFAULT_CONFIG The MFR_DEFAULT_CONFIG command is used to notify the host if any of the write-able registers of the LT3074 have been modified. A value of 0x01 indicates that all write-able registers are in their default configuration (as set upon a power on or a reset event). A value of 0x00 indicates that at least one write-able register has been modified from its default status. This command can be used to detect a BIAS UVLO event. This command has one data byte. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |