| Electronic Components Datasheet Search |
|
BMP585 Datasheet(PDF) 20 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMP585 Datasheet(HTML) 20 Page - Bosch Sensortec GmbH |
|
20 / 71 page ![]() Bosch Sensortec | BST-BMP585-DS003-02 20 | 71 © Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, Document number: BST-BMP585-DS003-02 as well as in the event of applications for industrial property rights 4.4 Measurements 4.4.1 Pressure and temperature measurement enable The BMP585 can either measure temperature only, or both temperature and pressure. Pressure-only measurement is not supported, as temperature data is needed for the temperature compensation of the pressure data.1 Pressure and temperature will be measured if any of these conditions is true: OSR_CONFIG.press_en ==1, or FIFO_SEL.fifo_frame_sel == 0b10, or FIFO_SEL.fifo_frame_sel == 0b11 If none of these settings is made, the sensor will measure temperature only. 4.4.2 Pressure and temperature oversampling ratio (OSR) Oversampling extends the measurement time per measurement by the oversampling factor. Higher oversampling factors offer decreased noise at the cost of higher power consumption. Oversampling can be set individually for pressure and temperature in register fields OSR_CONFIG.osr_p and OSR_- CONFIG.osr_t. The duration of the sampling phase is given by tconv_p and tconv_t. Table 7 shows the maximum ODR for each oversampling setting. Recommended settings are shown in Table 9. Table 9: Oversampling settings Oversampling setting osr_p Pressure oversampling Temperature oversampling Typical pressure RMS noise at 100 kPa Typical ODR in CONTINUOUS mode Lowest power 000 ×1 ×1 0.78 Pa 498 Hz 001 ×2 ×1 0.58 Pa 374 Hz Standard resolution 010 ×4 ×1 0.41 Pa 255 Hz 011 ×8 ×1 0.30 Pa 155 Hz High resolution 100 ×16 ×1 0.21 Pa 87 Hz 101 ×32 ×2 0.15 Pa 46 Hz 110 ×64 ×4 0.11 Pa 24 Hz Highest resolution 111 ×128 ×8 0.08 Pa 12 Hz Note: The noise values refer to the sensor-intrinsic noise. Already at standard resolution, the noise or fluctuations of the air pressure itself may be higher than the noise of the sensor, and thus be dominant. This ambient noise is typically stronger at lower frequencies. Any increase of the ODR does not reduce this type of noise, because this frequency range is of interest for many applications and thus is not attenuated by the sensor. If low frequency noise is a problem in a use case, it is recommended to employ low pass filtering, for example by using the build-in IIR-filter. 4.4.3 Configuration changes in NORMAL and CONTINUOUS mode If any of these changes is applied during NORMAL and CONTINUOUS mode: OSR_CONFIG.press_en OSR_CONFIG.osr_t OSR_CONFIG.osr_p ODR_CONFIG.odr (NORMAL mode only) Measurements will restart with the new settings after treconf. If DEEP_SLEEP is enabled in NORMAL mode, it will start after treconf_deep. 1 However, the sensor can be configured to output the pressure only data to the FIFO, see section 4.6.1 FIFO Configuration. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |