Back Button ADC32RF44 Datasheet HTML 71Page - Texas Instruments ADC32RF44 Datasheet HTML 72Page - Texas Instruments ADC32RF44 Datasheet HTML 73Page - Texas Instruments ADC32RF44 Datasheet HTML 74Page - Texas Instruments ADC32RF44 Datasheet HTML 75Page - Texas Instruments ADC32RF44 Datasheet HTML 76Page - Texas Instruments ADC32RF44 Datasheet HTML 77Page - Texas Instruments ADC32RF44 Datasheet HTML 78Page - Texas Instruments ADC32RF44 Datasheet HTML 79Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 75 / 128 page
background image
75
ADC32RF42
www.ti.com
SBAS844 – MAY 2017
Product Folder Links: ADC32RF42
Submit Documentation Feedback
Copyright © 2017, Texas Instruments Incorporated
9.5.7 Digital Gain Page (610005h, M = 1 for Channel A and 610105h, M = 1 for Channel B)
9.5.7.1 Register 0A6h (address = 0A6h), Digital Gain Page
Figure 109. Register 0A6h
7
6
5
4
3
2
1
0
0
0
0
0
DIGITAL GAIN
W-0h
W-0h
W-0h
W-0h
R/W-0h
Table 51. Register 0A6h Field Descriptions
Bit
Field
Type
Reset
Description
7-4
0
W
0h
Must write 0
3-0
DIGITAL GAIN
R/W
0h
These bits apply a digital gain to the ADC data (before the DDC)
up to 11 dB.
0000 = Default
0001 = 1 dB
1011 = 11 dB
Others = Do not use
9.5.8 Main Digital Page Channel A (680000h, M = 1)
9.5.8.1 Register 000h (address = 000h), Main Digital Page Channel A
Figure 110. Register 000h
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
DIG CORE RESET GBL
W-0h
W-0h
W-0h
W-0h
W-0h
W-0h
W-0h
R/W-0h
Table 52. Register 000h Field Descriptions
Bit
Field
Type
Reset
Description
7-1
0
W
0h
Must write 0
0
DIG CORE RESET GBL
R/W
0h
Pulse this bit (0
→1 →0) to reset the digital core (applies to both
channel A and B).
All Nyquist zone settings take effect when this bit is pulsed.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com