| Electronic Components Datasheet Search |
|
MFRC522 Datasheet(PDF) 50 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MFRC522 Datasheet(HTML) 50 Page - NXP Semiconductors |
|
50 / 109 page ![]() 112132 © NXP B.V. 2007. All rights reserved. Product data sheet Rev. 3.2 — 22 May 2007 50 of 109 NXP Semiconductors MFRC522 Contactless Reader IC 10.3.3 Framing Remark: For data and address bytes the LSB bit has to be sent first. No parity bit is used during transmission. Read data: To read out data using the UART interface the flow described below has to be used. The first send byte defines both the mode itself and the address. Table 141: UART Framing Length Value Start bit 1 bit 0 Data bits 8 bits Data Stop bit 1 bit 1 Table 142: Byte Order to Read Data byte 0 byte 1 RX adr TX data 0 Fig 9. Schematic Diagram to Read Data |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |