| Electronic Components Datasheet Search |
|
DRA752ABC Datasheet(PDF) 183 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
DRA752ABC Datasheet(HTML) 183 Page - Texas Instruments |
|
183 / 443 page ![]() 183 DRA756, DRA755, DRA754, DRA752 DRA751, DRA750, DRA746, DRA745, DRA744 www.ti.com SPRS950F – DECEMBER 2015 – REVISED MAY 2019 Submit Documentation Feedback Product Folder Links: DRA756 DRA755 DRA754 DRA752 DRA751 DRA750 DRA746 DRA745 DRA744 Specifications Copyright © 2015–2019, Texas Instruments Incorporated – Grey shaded areas show valid transition times for supplies between VOPR MIN and VOFF. – Dashed horizontal lines are not valid ramp times but show alternate transition times based upon common sources and clarified in associated note. – Dashed vertical lines show approximate elapse times based upon TI recommended PMIC power-down sequencer circuit performance. (4) porz signals must be asserted low for 100 µs min to ensure SoC is set to a safe functional state before any voltage begins to ramp down. (5) vddshv* domains supplied by 3.3 V: – must remain greater than 2.7 V to enable Dual Voltage GPIO selector circuit operation for 100 µs min after porz is asserted low. – must be in first group of supplies ramping down after porz has been asserted low for 100 µs min. – must not exceed vdds18v by more than 2 V during ramp down, see Figure 5-7 “vdds18v and vdda_* Discharge Relationship”. (6) vddshv* domains supplied by 1.8 V: – must ramp down concurrently with vdds18v and be sourced from the same vdds18v supply. (7) vddshv8 domain: – must be in first group of supplies to ramp down after porz has been asserted low for 100 µs min. – if SDIO operation is needed, must be sourced from independent power resource that can provide dual voltage (3.3 V / 1.8 V) operation as required to be compliant to SDIO specification – if SDIO operation is not needed, must be grouped and ramped down with other vddshv* domains as noted above. (8) RTC domains (vddshv5, vdd_rtc, and vdda_rtc): – If RTC mode is used: – rtc_porz can be asserted low before porz and RTC domains can be ramped down after 100 µs elapsed time. – must be sourced from independent supplies and must not be combined with other rails. – timing diagram shows this mode of operation. – If RTC mode is not used, then: – rtc_porz must be connected to porz signal. – vddshv5 must be grouped and ramped down with other vddshv* domains as noted above. – vdd_rtc must be grouped and ramped down with vdd. – vdda_rtc must be grouped and ramped down with either VDDA_PHY group or vdds18v. (9) vdda_* domains: – should not be combined with vdds18v for best performance to avoid transient switching noise impacts on analog domains. – can ramp down before or concurrently with vdds18v. – must satisfy the vdds18v and vdda_* Discharge Relationship (see Figure 5-7) if vdda_* disable point is later or discharge rate is slower than vdds18v. – can ramp down before, concurrently or after vdds_ddr*, there is no dependency between these supplies. (10) vdda33v_usb* domains: – can start ramping down 100 µs after low assertion of porz – can ramp down concurrently or before VDDA_PHY group (11) vdd_dspeve, vdd_gpu, vdd_iva, vdd_mpu domains can ramp down before or concurrently with vdd. (12) vdd can ramp down concurrently or after with vdd_dspeve, vdd_gpu, vdd_iva, vdd_mpu domains. (13) vdds_ddr* domains: – should ramp down after vdd begins ramping down. – If DDR2 memory is used (requiring 1.8 V supply): – then vdds_ddr* can be combined with vdds18v and vdds18v_ddr* domains and sourced from a common supply. Accordingly, all domains can ramp down concurrently with vdds18v – if vdds_ddr* and vdds18v_ddr* are combined but kept separate from vdds18v, then the combined 1.8 V DDR supply can ramp down before or concurrently with vdds18v (14) vdds18v domain: – should maintain VOPR MIN (VNOM -5% = 1.71 V) until all other supplies start to ramp down. – must satisfy the vdds18v versus vddshv[1-7, 9-11] Discharge Relationship (see Figure 5-5) if vddshv* is operating at 3.3 V – must satisfy the vdds18v and vdds_ddr* Discharge Relationship (see Figure 5-6) if vdds_ddr* discharge rate is slower than vdds18v. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |