14 / 22 page ![]() Data Sheet AD5172/AD5173 THEORY OF OPERATION analog.com Rev. J | 14 of 22 Figure 38. Detailed Functional Block Diagram The AD5172/AD5173 are 256-position, digitally controlled variable resistors (VRs) that employ fuse link technology to achieve memory retention of the resistance setting. An internal power-on preset places the wiper at midscale during power-on. If the OTP function is activated, the device powers up at the user-defined permanent setting. ONE-TIME PROGRAMMING (OTP) Prior to OTP activation, the AD5172/AD5173 presets to midscale during initial power-on. After the wiper is set to the desired position, the resistance can be permanently set by programming the T bit high, with the proper coding (see Table 8 and Table 9), and one-time VDD_OTP. The fuse link technology of the AD517x family of digital potentiometers requires VDD_OTP to be between 5.6 V and 5.8 V to blow the fuses to achieve a given nonvolatile setting. However, during operation, VDD can be 2.7 V to 5.5 V. As a result, an external supply is required for one-time programming. The user is allowed only one attempt to blow the fuses. If the user fails to blow the fuses during this attempt, the structure of the fuses can change such that they may never be blown, regardless of the energy applied during subsequent events. For details, see the Power Supply Considerations section. The device control circuit has two validation bits, E1 and E0, that can be read back to check the programming status (see Table 7). Users should always read back the validation bits to ensure that the fuses are properly blown. After the fuses are blown, all fuse latches are enabled upon subsequent power-on; therefore, the output corresponds to the stored setting. Figure 38 shows a detailed functional block diagram. Table 7. Validation Status E1 E0 Status 0 0 Ready for programming. 1 0 Fatal error. Some fuses are not blown. Do not retry. Discard this unit. 1 1 Successful. No further programming is possible. PROGRAMMING THE VARIABLE RESISTOR AND VOLTAGE Rheostat Operation The nominal resistance of the RDAC between Terminal A and Terminal B is available in 2.5 kΩ, 10 kΩ, and 100 kΩ. The nominal resistance (RAB) of the VR has 256 contact points accessed by the wiper terminal and the B terminal contact. The 8-bit data in the RDAC latch is decoded to select one of the 256 possible settings. Figure 39. Rheostat Mode Configuration Assuming a 10 kΩ part is used, the first connection of the wiper starts at the B terminal for Data 0x00. Because there is a 160 Ω wiper contact resistance, such a connection yields a minimum of 320 Ω (2 × 160 Ω) resistance between Terminal W and Terminal B. The second connection is the first tap point, which corresponds to 359 Ω (RWB = RAB/256 + 2 × RW = 39 Ω + 2 × 160 Ω) for Data 0x01. The third connection is the next tap point, representing 398 Ω (2 × 39 Ω + 2 × 160 Ω) for Data 0x02, and so on. Each LSB data value increase moves the wiper up the resistor ladder until the last tap point is reached at 10281 Ω (RAB − 1 LSB + 2 × RW). Figure 40. AD5172/AD5173 Equivalent RDAC Circuit |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |