Electronic Components Datasheet Search
  English  ▼

X  

6266 Datasheet(PDF) 12 Page - THAT Corporation All rights reserved.

Part # 6266
Description  2-Channel Low-Noise Programmable-Gain Preamplifier - ADC Driver IC
PDF  20 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  THAT [THAT Corporation All rights reserved.]
Direct Link  https://thatcorp.com/
Logo THAT - THAT Corporation All rights reserved.

6266 Datasheet(HTML) 12 Page - THAT Corporation All rights reserved.

Back Button 6266 Datasheet HTML 8Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 9Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 10Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 11Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 12Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 13Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 14Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 15Page - THAT Corporation All rights reserved. 6266 Datasheet HTML 16Page - THAT Corporation All rights reserved. Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 20 page
background image
Document 600190 Rev 05
Page 12 of 20
THAT 626x 2-Channel Low-Noise Programmable
Gain Preamplifier – ADC Driver IC
THAT Corporation; 45 Sumner Street; Milford, Massachusetts 01757-1656; USA
Tel: +1 (508) 478-9200; Fax +1 (508) 478-0990; Web: www.thatcorp.com
Copyright © 2018, THAT Corporation; All rights reserved.
GPO State
Two General Purpose Outputs (GPOs) are asso-
ciated with each channel. GPO_CH1[1:0] are for
channel 1 while GPO_CH2[1:0] are for channel 2.
Each of the GPO bits controls the state of the respec-
tive GPO_CH1/2 pins as shown in Table 8 below.
On reset, all GPOs are set to their default state of
all ports off.
Channel Enable (vs. Standby)
Each channel may be enabled or set to a low-
power Standby mode through the SPI port by its as-
sociated active-high enable bit: EN_CH1 controls
channel 1 and EN_CH2 controls channel 2. When
EN_CHx=1, channel x’s analog circuitry is biased for
normal operation. When EN_CHx=0, channel x’s
analog circuitry enters a low-power stand-by state,
and the current status of all channel x’s registers is
reserved. Any of channel x’s registers may be updates
while the channel is kept in standby mode. Bringing
the EN_CH1 or EN_CH2 registers back to 1 via SPI
will restore the last written state of other registers.)
On reset, both channels are set to standby (00).
Channel MUTE
There are two active-high mute bits, MT_CH1 for
channel 1 and MT_CH2 for channel 2. Assuming the
relevant channel is enabled, setting the MT_CHx reg-
ister high will mute channel x‘s output by more than
60 dB. When a channel is in mute mode, its pream-
plifier stage is set to unity gain while its ADC driver
stage is configured for over 60dB attenuation. Setting
MT_CHx low returns channel x’s gain to the last value
previously set (which remains stored in the gain reg-
isters).
When programmed, mute is effective immediate-
ly independently of the setting of ZCD enable.
While a channel is muted, its gain programma-
bility is still active and the register gain settings can
be programmed to any desired value. Gains set in
this way will be implemented when the channel is
unmuted.
Note that when EN_CHx=0 (channel x is in
standby), MT_CHx is invalid and will be ignored.
On reset, both channels are set to the un-muted
state (00).
Zero Crossing Detector (ZCD) Enable
The zero-crossing detectors are enabled for gain
and GPO changes via the GMD and GPOMD bits,
respectively. There is only one control for both chan-
nels; their states must be the same in both.
When GMD=1, upon transmission of an SPI gain
change command to an enabled channel, gain chang-
es are held until the signal crosses zero at that chan-
nel’s ADC driver output. When GMD=0 gain setting
changes to either enabled channel are applied imme-
diately (regardless of the GPOMD setting).
When GPOMD=1 and a channel is enabled, up-
on transmission of an SPI command that changes the
setting of GPO_CHx[1:0], the change of state at that
GPO output is held until the signal crosses zero at
channel x’s ADC driver output. When GPOMD=0
(and that channel is enabled) and GMD=0, any
changes to GPO_CHx[1:0] are effective immediately.
Table 9 shows the bit settings for each of the modes.
On reset, the ZCDs are set to their default state
of off for both GPOMD and GMD (00).
Controlling Multiple Devices
When using multiple 626x devices in the same
product, the SPI ports can be controlled in “parallel”
by using a separate chip select for each device, or in
“serial” by daisy-chaining the devices.
GPO
Channel
GPO #
State
GPO_CH1[0]
1
1
0=off (0V);
1= on
(3.3V)
GPO_CH1[1]
1
2
GPO_CH2[0]
2
1
GPO_CH2[1]
2
2
Table 8. GPO bit settings.
GPOMD
GMD
Resulting Condition
X
0
Immediate Gain updates
X
1
Gain update synchronized with
ZCD event
0
X
Immediate GPO updates
1
X
GPO updates synchronized
with ZCD event
Table 9. Zero crossing detector enable bits.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com