| Electronic Components Datasheet Search |
|
MAX9526 Datasheet(PDF) 12 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX9526 Datasheet(HTML) 12 Page - Maxim Integrated Products |
|
12 / 38 page ![]() Sync Processing The sync processing block extracts the sync information and automatically detects 525 line or 625 line inputs. Clock Generator and PLL The PLL operates in either line-locked clock (LLC) mode or async mode. Selection of the mode is con- trolled automatically by the MAX9526 or can optionally be overwritten with the LLC_MODE bits in PLL Control register 0x0E. In LLC mode, a hybrid analog/digital PLL generates a low-jitter line-locked clock. The 54MHz sample clock is synchronous to the input video. The LLC clock output is also synchronous to the input video. The ITU output has the correct number of samples per line and lines per field. The PLL is designed to lock to signals with up to 160ns peak jitter. When the jitter exceeds the 160ns peak, the PLL coasts until the jitter improves. If the jitter continuously exceeds the 160ns peak, the PLL relocks and the HLOCK status bit in register 0x00 is set to 0. In LLC mode, the bandwidth of the PLL can be option- ally programmed to one of eight values between 180Hz and 2000Hz using the PLLBW bits in PLL Control regis- ter 0x0E. The default value for the PLL bandwidth is 500Hz. In async mode, the sample clock frequency is generat- ed by multiplying the crystal frequency by a factor of two and the video signal is sampled asynchronously with the 2x crystal clock. To eliminate artifacts, the MAX9526 uses an adaptive poly-phase filter to correct timing and phase errors introduced by the asynchro- nous sampling. The LLC output is generated by divid- ing the 54MHz sampling clock by two. The ITU output in async mode has the correct number of lines per frame and the correct number of pixels per line except on the first line of each field. The timing correc- tion block uses this line to compensate for timing errors between the incoming video signal and the crystal. As a result, the first line of each field is longer or shorter for several pixels depending on the magnitude of the fre- quency difference between the incoming video signal and the local crystal. For example, a 100ppm frequency difference between the incoming video signal and the crystal results in approximately 23 extra or fewer pixels on the first line of each field. Line length errors on line one are of no consequence for most applications since it is in the vertical blanking interval and does not contain active video or any other type of data. The types of inputs that cause the PLL to automatically switch to async mode are video inputs with a nonstan- dard carrier frequency. For standard video, the carrier frequency is always a precise multiple of the horizontal frequency. A typical nonstandard input is video cassette recorders in which the carrier is not a precise multiple of the horizontal frequency. The nonstandard detect (NONSTD) status from the decoder is used to automati- cally switch the PLL to async mode when nonstandard carrier frequencies are detected. The NONSTD status is monitored in the Status register 0x00. Clocking Modes In addition to automatic configuration, the MAX9526 can also be manually configured to provide maximum flexibility in setting the clock inputs and outputs of the chip. Table 1 summarizes the clocking modes that are supported. Digital Composite Decoding Figure 3 shows a block diagram of the digital compos- ite decoder. This block converts the digitized compos- ite video signal to digital component video. Sync Level Correction and Sync Extraction The sync extraction function extracts the raw sync sig- nals from the video and the extracted sync information is sent to the sync processor. The sync level from the AFE is code 32 (decimal) on a 10-bit scale and the blanking level is approximately 208 (decimal) codes above the sync level. The sync slicer default threshold is set to approximately the middle of the sync pulse at decimal code 128. The sync slice level can optionally be manually adjusted using the slice bits in register 0x0F. The sync level correction block features an optional digital clamp that can be enabled in register 0x09. Enabling the digital clamp sets the sync level to code 0 (decimal) and gives higher frequency tracking of the input signals. When the digital clamp is enabled, the sync slice level in register 0x0F should be adjusted accordingly to provide equivalent noise rejection. Sync Processor and Analog Copy Protection Detection The sync processor extracts the horizontal sync and vertical sync signals. Field pulses and burst gate puls- es are generated based on VSYNC and HSYNC, respectively. The sync processing block provides sync timing to measure the sync level and amplitude for the black level control and composite AGC. The sync processor also detects incoming video signal stan- dards (525 line NTSC and 625 line PAL). Video stan- dard information is available in Status register 0x01. The detected video standard is used to automatically configure the decoder. The MAX9526 detects NTSC-M (standard NTSC) and PAL B/G/H/I/D (standard PAL) Low-Power, High-Performance NTSC/PAL Video Decoder 12 ______________________________________________________________________________________ |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |