Electronic Components Datasheet Search
  English  ▼

X  

ADM1276 Datasheet(PDF) 25 Page - Analog Devices

Part # ADM1276
Description  Hot Swap Controller and Digital Power and Energy Monitoring with PMBus Interface
PDF  48 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AD [Analog Devices]
Direct Link  http://www.analog.com
Logo AD - Analog Devices

ADM1276 Datasheet(HTML) 25 Page - Analog Devices

Back Button ADM1276 Datasheet HTML 21Page - Analog Devices ADM1276 Datasheet HTML 22Page - Analog Devices ADM1276 Datasheet HTML 23Page - Analog Devices ADM1276 Datasheet HTML 24Page - Analog Devices ADM1276 Datasheet HTML 25Page - Analog Devices ADM1276 Datasheet HTML 26Page - Analog Devices ADM1276 Datasheet HTML 27Page - Analog Devices ADM1276 Datasheet HTML 28Page - Analog Devices ADM1276 Datasheet HTML 29Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 48 page
background image
ADM1276
Rev. 0 | Page 25 of 48
SMBus MESSAGE FORMATS
Figure 52 to Figure 60 show all the SMBus protocols supported
by the ADM1276, along with the PEC variant. In these figures,
unshaded cells indicate that the bus host is actively driving the
bus; shaded cells indicate that the ADM1276 is driving the bus.
Figure 52 to Figure 60 use the following abbreviations:
S is the start condition.
Sr is the repeated start condition.
P is the stop condition.
R is the read bit.
W is the write bit.
A is the acknowledge bit (0).
A is the acknowledge bit (1).
“A” represents the acknowledge bit. The acknowledge bit is typi-
cally active low (Logic 0) if the transmitted byte is successfully
received by a device. However, when the receiving device is the
bus master, the acknowledge bit for the last byte read is a Logic 1,
indicated by A.
SP
A
A
W
SLAVE ADDRESS
DATA BYTE
S
P
A
A
W
SLAVE ADDRESS
DATA BYTE
PEC
A
MASTER TO SLAVE
SLAVE TO MASTER
Figure 52. Send Byte and Send Byte with PEC
SP
A
A
R
SLAVE ADDRESS
DATA BYTE
S
P
A
A
R
SLAVE ADDRESS
DATA BYTE
PEC
MASTER TO SLAVE
SLAVE TO MASTER
A
Figure 53. Receive Byte and Receive Byte with PEC
SA
A
W
SLAVE ADDRESS
COMMAND CODE
DATA BYTE
P
A
SA
A
W
SLAVE ADDRESS
COMMAND CODE
DATA BYTE
P
A
PEC
A
MASTER TO SLAVE
SLAVE TO MASTER
Figure 54. Write Byte and Write Byte with PEC
A
SLAVE ADDRESS
R
DATA BYTE
Sr
A
A
S
A
A
W
SLAVE ADDRESS
COMMAND CODE
P
A
PEC
SA
A
W
SLAVE ADDRESS
COMMAND CODE
SLAVE ADDRESS
P
RDATA BYTE
Sr
A
MASTER TO SLAVE
SLAVE TO MASTER
Figure 55. Read Byte and Read Byte with PEC
P
SA
A
W
SLAVE ADDRESS
COMMAND CODE
DATA BYTE LOW
A
A
SA
A
W
SLAVE ADDRESS
COMMAND CODE
DATA BYTE LOW
ADATA BYTE HIGH
DATA BYTE HIGH
A
P
A
PEC
MASTER TO SLAVE
SLAVE TO MASTER
Figure 56. Write Word and Write Word with PEC



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com