Back Button ACMAXX Datasheet HTML 12Page - ebm-papst ACMAXX Datasheet HTML 13Page - ebm-papst ACMAXX Datasheet HTML 14Page - ebm-papst ACMAXX Datasheet HTML 15Page - ebm-papst ACMAXX Datasheet HTML 16Page - ebm-papst ACMAXX Datasheet HTML 17Page - ebm-papst ACMAXX Datasheet HTML 18Page - ebm-papst ACMAXX Datasheet HTML 19Page - ebm-papst ACMAXX Datasheet HTML 20Page - ebm-papst Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 192 page
background image
16
Definitions
Nominal voltage (Volts)
The voltage at which the nominal values (the ta-
bular values listed in this catalogue) were deter-
mined. The fan operation for DC fans is not lim-
ited to the nominal voltage. Fan speed and fan
performance can vary according to the permis-
sible voltage range that is specified on the
nameplate of each fan.
Frequency (Hz)
ebm-papst AC fans are made for operating fre-
quencies of 50 Hz or 60 Hz. Their technical data
alter accordingly.
Air flow (m3/h)
The air performance of the fan in free air opera-
tion, i.e. the fan blows into the free space with-
out static pressure build-up.
Fan curves
The fan curves are determined in accordance
with DIN 24 163 specifications on a dual-cham-
ber test stand with intake-side measurement.
This measurement technique closely approxi-
mates the operating conditions experienced in
typical applications for fans and yields realistic
performance curves. The curves apply to an air
density of
ρ = 1.2 kg/m3, corresponding to an
air pressure of 1013 mbar at 20 °C. Variations in
air density affect pressure generation but not
the flow rate. The pressure generated at other
air densities may be estimated with the formula
Δρ2= Δρ1(ρ2/ ρ1).
The nominal speed values, air flow and power
input listed in the table were measured in free
air operation with horizontal shaft at an ambient
temperature of 20 +5 °C, air density
ρ = 1.2 kg/m3 after a warm-up period of 5 min.
Optimum operating range
During operation, fans are required to produce
an air flow with a simultaneous increase of
pressure. These operating conditions are
described in the section “Optimum Operating
Range”. The optimum operating range is there-
fore always indicated in this catalogue in the
shaded area. In this range the fans operate best
with respect to efficiency and noise level. Within
this optimum operating range the noise level
only fluctuates insignificantly.
Noise [dB(A), Bel(A)]
1. Sound pressure level – dB(A)
Noise ratings of the fan in free air operation, i.e.
at maximum flow rate.
2. Sound power level – Bel(A) / dB(A)
Extent of the overall sound radiation of the fan.
The sound power level is determined in the
optimum operating range.
PAPST Sintec® sleeve bearings
A particularly efficient bearing system with
excellent qualities:
– Very precise, large sintered bearings
– Low running noise
– High service life expectancy
– Insensitive to shock and vibration
Ball bearings
Precision ball bearings for particularly high
ambient temperatures and high service life
expectancy.
Power input (Watts)
Input performance of the fan motor when
operating at nominal voltage. Depending on the
operating condition in the application, the power
input may be higher.
Temperature range (°C)
The permissible ambient temperature range
within which the fan can be expected to run
continuously.
Service life [h]
Service life L10 at 40°C and Tmax
Standard figures for service life at ebm-papst.
These two temperatures are based on intensive,
in-house endurance tests and on the experience
more than 60 years developing fans.
Life expectancy L10ΔΔ (40°C)
Figures oriented towards the calculation metho-
ds employed by other fan manufacturers. Data
based on the internal expected service life at
70°C, more optimistically extrapolated to 40°C.
We expressly state that none of the informa-
tion or data in this catalogue is to be con-
strued as a guarantee or warranty of proper-
ties.
Unit conversion
Air flow
Pressure
1cfm = 1,7 m3/h
1Pa = 1x10-5bar
1l/s = 3,6 m3/h
1 inch H2O = 249 Pa
1l/min = 0,06 m3/h
1 mm H2O = 9,81 Pa
0
1
2
10
20
15
3
4
m³/h
5
25
30
35
Optimum Operating
Range
Fan Curve
CFM
0,4
0,8
1,2
1,6
2,0
Subject to technical alterations.
Our products are not designed for use in the aerospace indu-
stry!
German and international patents, registered designs and uti-
lity models.
ebm-papst is a registered trademark of ebm-papst Mulfingen
GmbH & Co. KG.
PAPST, SINTEC, VARIOFAN and Vario-Pro are registered trade-
marks of ebm-papst St. Georgen GmbH & Co. KG.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com