28 / 56 page ![]() ADM1026 Rev. A | Page 28 of 56 ADM1026 Interrupt Structure The Interrupt Structure of the ADM1026 is shown in Figure 53. Interrupts can come from a number of sources, which are com- bined to form a common INT output. When INT is asserted, this output pulls low. The INT pin has an internal, 100 kΩ pull-up resistor. Analog/Temperature Inputs As each analog measurement value is obtained and stored in the appropriate value register, the value and the limits from the corresponding limit registers are fed to the high and low limit comparators. The device performs greater than comparisons to the high limits. An out-of-limit is also generated if a result is less than or equal to a low limit. The result of each comparison (1 = out of limit, 0 = in limit) is routed to the corresponding bit input of Interrupt Status Register 1, 2, or 4 via a data demultiplexer, and used to set that bit high or low as appro- priate. Status bits are self-clearing. If a bit in a status register is set due to an out-of-limit measurement, it continues to cause INT to be asserted as long as it remains set, as described later. However, if a subsequent measurement is in limit, it is reset and does not cause INT to be reasserted. Status bits are unaffected by clearing the interrupt. Interrupt Mask Registers 1, 2, and 4 have bits corresponding to each of the interrupt status register bits. Setting an interrupt mask bit high conceals an asserted status bit from display on Interrupt Pin 17. Setting an interrupt mask bit low allows the corresponding status bit to be asserted and displayed on Pin 17. After mask gating, the status bits are all OR’ed together to produce the analog and fan interrupt that is used to set a latch. The output of this latch is OR’ed with other interrupt sources to produce the INT output. This pulls low if any unmasked status bit goes high, that is, when any measured value goes out of limit. When an INT output caused by an out-of-limit analog/ temperature measurement is cleared by one of the methods described later, the latch is reset. It is not set again, and INT is not reasserted until after two local temperature measure-ments have been taken, even if the status bit remains set or a new analog/temperature event occurs, as shown in Figure 50. This delay corresponds to almost two monitoring cycles, and is about 530 ms. However, interrupts from other sources such as a fan or GPIO can still occur. This is illustrated in Figure 51. START OF ANALOG MONITORING CYCLE OUT-OF-LIMIT MEASUREMENT START OF ANALOG MONITORING CYCLE INT INT CLEARED LOCAL TEMPERATURE MEASUREMENT START OF ANALOG MONITORING CYCLE INT RE-ASSERTED OUT-OF-LIMIT MEASUREMENT FULL MONITORING CYCLE = 273ms TEMPERATURE LOCAL MEASUREMENT Figure 50. Delay After Clearing INT Before Reassertion START OF ANALOG MONITORING CYCLE OUT-OF-LIMIT MEASUREMENT LOCAL TEMPEREATURE MEASUREMENT START OF ANALOG MONITORING CYCLE LOCAL TEMPERATURE MEASUREMENT START OF ANALOG MONITORING CYCLE INT CLEARED INT RE-ASSERTED NEW INT FROM FAN NEW INT FROM GPIO GPIO DE-ASSERTED INT INT CLEARED Figure 51. Other Interrupt Sources Can Reassert INT Immediately |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |