| Electronic Components Datasheet Search |
|
RH850 Datasheet(PDF) 49 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
RH850 Datasheet(HTML) 49 Page - Renesas Technology Corp |
|
49 / 66 page ![]() Data Flash Access Library - Type T01, European Release User Interface (API) R01US0079ED0103 49 User Manual Internally blankcheck operation is split into smaller operations every time the operation crosses a 4. 0x4000 bytes boundary. This means that time to suspend is not going to exceed the time to fully perform a blankcheck on 0x4000 bytes. The members of the request structure given to R_FDL_Execute are described in the following table: Table 7: Request structure usage for blank check command Structure member Value Description command_enu R_FDL_CMD_BLANKCHECK Request a blank check operation bufAddr_u32 - Not used idx_u32 {uint32_t number} Input: The virtual start address for performing blank check in data flash. Must be word (4 bytes) aligned. Output: Fail address in case of blank check error, unchanged if the operation finishes with R_FDL_OK. cnt_u16 {uint16_t number} Number of words (4 bytes) to check accessType_enu R_FDL_ACCESS_USER / R_FDL_ACCESS_EEL Selects the Flash pool in which the command will be able to operate. status_enu - This is an output member. It contains the status of the operation during and after the execution. Possible values are described in the next table. The following table describes all possible status returns: Table 8: Blank check operation returned status Status Background and Handling R_FDL_BUSY meaning Operation started successfully reason No problems during execution remedy Call R_FDL_Handler until the Flash operation is finished, reported by the request structure status return value R_FDL_OK (1) meaning Operation finished successfully reason No problems during execution remedy Nothing R_FDL_SUSPENDED (1) meaning An on-going Flash operation was successfully suspended reason Suspend processing successfully finished remedy Start another operation or resume the suspended operation R_FDL_ERR_PARAMETER (2) meaning Current command is rejected |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |